NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street, Suite 200
'aceAnalyticar Minneapolis, MN 55414
Phone: 612.607.1700
www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444
PROJECT: PCDD/PCDF ANALYSES DATE: January 3, 2002
PAGE: 8 REPORT NO: 01-1052125
RESULTS
The results from the analyses are included in the following:
Appendix A - Chain of Custody Documentation
Appendix B - PCDD/PCDF Analysis Results
DISCUSSION
The recoveries of the isotopically labeled PCDD/PCDF internal standards in the air sample extracts
ranged from 20-103%, indicating a level of efficiency through the extraction and enrichment steps
that is considered typical to low for this matrix. A number of these values were below the target
range of the method. However, since the internal standards were added to the samples prior to the
extraction step, the data were automatically corrected for recovery and accurate values were
obtained.
The recoveries of the spiked PCDD/PCDF surrogate compounds in the samples ranged from 87-
131 %. With the exception of one surrogate, which were affected by an interfernce, these values
were all within the range specified in Method 23. This indicates that analyte breakthrough did not
occur during sampling.
A laboratory method blank was prepared and analyzed with the sample batch as part of our routine
quality control procedures. The results, found at the beginning of Appendix B, show the blank to
contain trace levels of selected PCDD isomers. These levels were below the calibration range of
: the method. Some of the samples contained the isomers at levels similar to that seen in the blank
[■ and are flagged "B" on the data summary sheets. In general, levels less than ten times the
background are not considered statistically differentJrom the background. It should be noted that
the blank appears to have been spiked with less than the typical amount of internal standards.
: Therefore, the native analyte levels reported for the blank should be considered high estimate
values. It is believed that the true values for the blank are approximately 40% lower than the
reported concentrations, based on the surrogate recoveries in the blank.
Laboratory quality control PCDD/PCDF spike samples were also prepared with the sample batch by
extracting clean PUF cartridges that had been fortified with native standard materials. The results,
included at the end of Appendix B, show that the spiked native compounds were recovered at 90_-
123% with relative percent differences of 1.0-21.6%. These results indicate high levels of
accuracy and precision for these analyses. It should be noted that a number of internal standards
in the laboratory spike sample were below the target range for this method.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
.nefec-
CITY_21MC100_002890300
NYC-WTC_000395793