NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 16 pages

Analytical lab report: PCBs/PCDFs

Machine-extracted title · confidence 42%

Attachment: analytical laboratory report for PCBs and PCDDs/PCDFs, NYC-WTC file.

NYC-WTC_000310760–000310775
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 'ace Analytical' Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.507.6444

PROJECT: PCDD/PCDF ANALYSES DATE: February 1, 2002

PAGE: 8 REPORT NO: 02-1053169

RESULTS

The results from the analyses are included in the following:

Appendix A - Chain of Custody Documentation Appendix B - PCDD/PCDF Analysis Results

DISCUSSION

The recoveries of the isotopically labeled PCDD/PCDF internal standards in the air sample extracts '3 generally ranged from 46-108%, indicating a level of efficiency through the extraction and enrichment steps that is considered typical for this matrix. Sample PI exhibited somewhat lower ' ’ recoveries (16-30%). With the exception of this sample, the internal standard recoveries were within the target range of the method. Also, since the internal standards were added to the samples prior to the extraction step, the data were automatically corrected for recovery and accurate values were obtained.

The recoveries of the spiked PCDD/PCDF surrogate compounds in the samples ranged from 82- 139%. With the exception of two surrogates, all of these values were all within the range specified in Method 23. This indicates that analyte breakthrough did not occur during sampling.

A laboratory method blank was prepared and analyzed with the sample batch as part of our routine - quality control procedures. The results, found at the beginning of Appendix B, show the blank to contain a trace level of OCDD. This level was below the calibration range of the method. Several of the samples contained this isomer at a level similar to that seen in the blank and are flagged "B" on the data summary sheets. In general, levels less than ten times the background are not considered statistically different from the background. This indicates that the sample preparation . procedures did not significantly impact the results of the field sample determinations.

. Laboratory quality control PCDD/PCDF spike samples were also prepared with the sample batch by ! extracting clean PUF cartridges that had been fortified with native standard materials. The results, included at the end of Appendix B, show that the spiked native compounds were recovered at 113- 150% with relative percent differences of 0.0-5.2%. The spike recoveries indicate a high bias. This bias was most likely introduced at the time of spiking the native analytes and would not impact the sample results. However, if it was due to a different cause, the sample results could also be biased high by approximately 30%.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

irie^ri CITY_21MC100_003029026

NYC-WTC_000310769

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000310769Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000395804

Chain-of-Custody data sheet for Pace Analytical project 6526-0279.

Similar indexed content

NYC-WTC_000396362

Pace Analytical chain-of-custody form accompanying a 31-page lab report package.

Similar indexed content

NYC-WTC_000396324

Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.

Similar indexed content

NYC-WTC_000396381

PACE chain-of-custody accompanying a 30-page Pace Analytical report package.

Similar indexed content

NYC-WTC_000395823

Pace Analytical chain-of-custody form, project data and page count note.

Similar indexed content

Compare copies and versions →