PCDD/PCDF Analyses
Each sample extract was analyzed for the presence of PCDDs and PCDFs using combined
capillary column gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The
instrumentation consisted of a Hewlett Packard Model 6890 gas chromatograph interfaced to a
Micromass Ultima high-resolution mass spectrometer. The capillary column was interfaced
directly into the ion source of the mass spectrometer, thus providing the highest possible
, sensitivity while minimizing degradation of the chromatographic resolution.
The mass spectrometer was operated in the electron impact ionization mode at a mass resolution
of 10,000-11,000 (M/AM, 10 percent valley definition). This resolution is sufficient to resolve
most interferences, such as PCBs, thus providing the highest level of confidence that the detected
levels of PCDDs are not false positives resulting from interferences. Typical operating parameters
for the HRGC/HRMS analyses are summarized in Table 2.
The data were acquired by selected-ion-recording (SIR) monitoring of the groups of ion masses
described in USEPA Method 23. The five groups corresponded to the tetrachlorinated through
octachlorinated congener classes. Each group contained two ion masses for the PCDDs, two ion
masses for the PCDFs,, the corresponding ion masses from the two isotopically labeled internal
standards, and the ion mass characteristic of the polychlorinated diphenylether (PCDPE) which, if
present, could cause false responses in the dibenzofuran channels.
Each group of ion masses also contained a lock mass which was .monitored during the analyses to. ,
detect suppressive interferences. It is particularly important to detect this type of interference
; since it can cause the quantification of congener class levels to be artificially high if it occurs duririg
! \ the elution of an internal standard or low if it occurs during the elution of the native analytes.