NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Chain-of-custody form, Pace Analytical

Machine-extracted title · confidence 42%

Chain-of-custody accompanying a Pace Analytical lab report for the project, listing client and sample identifiers.

NYC-WTC_000396324–000396338
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 'ace Analyticar Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: January 3, 2002

PAGE: 3 REPORT NO: 01-1052125

PCDD/PCDF Analyses

Each sample extract was analyzed for the presence of PCDDs and PCDFs using combined capillary column gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The instrumentation consisted of a Hewlett Packard Model 6890 gas chromatograph interfaced to a Micromass Ultima high-resolution mass spectrometer. The capillary column was interfaced direcfiy into the ion source of the mass spectrometer, thus providing the highest possible ' sensitivity while minimizing degradation of the chromatographic resolution.

The mass spectrometer was operated in the electron impact ionization mode at a mass resolution of 10,000-11,000 (M/AM, 10 percent valley definition). This resolution is sufficient to resolve most interferences, such as PCBs, thus providing the highest level of confidence that the detected levels of PCDDs are not false positives resulting from interferences. Typical operating parameters for the HRGC/HRMS analyses are summarized in Table 2.

The data were acquired by selected-ion-recording (SIR) monitoring of the groups of ion masses described in USEPA Method 23. The five groups corresponded, to the tetrachlorinated through octachlorinated congener classes. Each group contained two ion masses for the PCDDs, two ion masses for the PCDFs, the corresponding ion masses from the two isotopically labeled internal i standards, and the ion mass characteristic of the polychlorinated diphenylether (PCDPE) which, if present, could cause false responses in the dibenzofuran channels.

2 Each group of ion masses also contained a lock mass which was monitored during the analyses to. . detect suppressive interferences. It is particularly important to detect this type of interference since it can cause the quantification of congener class levels to be artificially high if it occurs during k the elution of an internal standard or low if it occurs during the elution of the native analytes.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, ’ without the written consent of Pace Analytical Services, Inc.

izoem CITY_21MC100_002891173

NYC-WTC_000396327

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000396327Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000395785

Chain-of-Custody document for Pace Analytical lab data and pages count.

Similar indexed content

NYC-WTC_000396381

PACE chain-of-custody accompanying a 30-page Pace Analytical report package.

Similar indexed content

NYC-WTC_000395823

Pace Analytical chain-of-custody form, project data and page count note.

Similar indexed content

NYC-WTC_000396362

Pace Analytical chain-of-custody form accompanying a 31-page lab report package.

Similar indexed content

NYC-WTC_000395804

Chain-of-Custody data sheet for Pace Analytical project 6526-0279.

Similar indexed content

Compare copies and versions →