NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis. MN 55414
^ace Analytical_________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax; 612- 607-6444
Client - ATC
Client's Sample ID ATC-0402-234M-DX1
Lab Sample ID 103451308
Filename U20425D_07
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/02/2002
ICAL Date 04/16/2002 Received 04/09/2002
CCal Filename(s) U20425C_16 & U20425D_16 Extracted 04/19/2002
Method Blank ID BLANK-1581 Analyzed 04/26/2002 11:54
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0057 0.0047 JA 2,3,7,8-TCDF-13C 2.00 59
Total TCDF 0.1300 0.0020 2,3,7,8-TCDD-13C 2.00 65
1,2,3,7.8-PeCDF-13C 2.00 68
2,3,7.8-TCDD ND 0.0029 A 2,3.4,7,8-PeCDF-13C 2.00 67
Total TCDD 0.2000 0.0020 1,2,3,7,8-PeCDD-13C 2.00 77
1,2,3,4,7,8-HxCDF-13C 2.00 73
1,2,3,7,8-PeCDF- ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 72
2,3,4,7,8-PeCDf- ND 0.0100 2,3,4,6,7.8-HxCDF-13C 2.00 69
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 72
1,2,3,4,7,8-HxCDD-13C 2.00 75
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 72
Total PeCDD 0.0850 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 72
1,2,3,4,7.8,9-HpCDF-13C 2.00 74
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6.7,8-HpCDD-13C 2.00 80
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C . 4.00 78
2,3,4,6,7,8-HxCDF ND 0.0100
1.2.3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 74
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.0180 0.0100 J
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00070 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3.4,6.7.8-HpCDD 0.0130 0.0100 J
Total HpCDD 0.0130 0.0100 J
OCDF ND 0.0200
OCDD 0.058 0.0200 I
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,6-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected Is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1056080
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002889396
NYC-WTC_000395215
OCR can misread numbers and units. Confirm readings against the page image before using them.