NYC-WTC_000240234
Laboratory analysis report from Pace Analytical for NYC WTC material, 2008 protective-order context.
3 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Laboratory analysis report; confidential and NYC-WTC related.
NYC-WTC_000240216–000240223OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Pace Analytical Services, Inc. 1700 Elm Street - Suite 200 Minneapolis, MN 55414
^ace Analytical___________ Method 8290 Analysis Results Tel: 612-607-1700 Fax- 612- 607-6444
I Client - ATC Client's Sample ID ATC-0316-M894-DX1 Lab Sample ID 103398939 Filename U20406A_07 Injected By BAL Total Amount Extracted 1 m2 Matrix WIPE % Moisture NA Dilution NA Dry Weight Extracted NA Collected 03/16/2002 ICAL Date 03/25/2002 Received 03/19/2002 CCal Filename(s) U204056A_01 & U20406A_08 Extracted 04/01/2002 Method Blank ID BLANK-1546 Analyzed 04/06/2002 23:03 Native Cone EMPC LRL Internal ng's Percent Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery 2,3,7,8-TCDF ND 0.0028 A 2.3,7,8-TCDF-13C 2.00 64 Total TCDF 0.035 0.0020 2,3,7,8-TCDD-13C 2.00 63 1,2,3,7,8-PeCDF-13C 2.00 68 2,3,7.8-TCDD ND 0.0033 A 2,3,4,7,8-PeCDF-13C 2.00 68 Total TCDD 0.063 0.0020 1,2,3,7,8-PeCDD-13C 2.00 65 1,2,3,4,7,8-HxCDF-13C 2.00 88 u 1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6.7,8-HXCDF-13C 2.00 71 2,3,4.7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 70 Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 71 1,2,3,4,7,8-HxCDD-13C 2.00 89 1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 59 Total PeCDD 0.030 0.0100 J 1,2,3,4,6,7,8-HpCDF-13C 2.00 74 1,2,3,4,7,8,9-HpCDF-13C 2.00 61 I 1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 61 -J 1,2,3,6,7,B-HxCDF ND 0.0100 OCDD-13C 4.00 49 2,3,4,6,7.8-HxCDF ND 0.0100 1,2,3,7,8,9-HxCDF ND 0.0100 1.2,3,4-TCDD-13C 2.00 NA Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 65 1,2,3,6,7,8-HxCDD ND 0.0100 1,2,3,7,8,9-HxCDD ND 0.0100 Total HxCDD 0.019 0.0100 J
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3.7,8-TCDD 1,2,3,4,7,8.9-HpCDF ND 0.0100 Equivalence; 0.00016 ng/m2 Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.010 0.0100 J Total HpCDD 0.024 0.0100 J OCDF ND 0.0200 OCDD 0.056 0.0200 BJ
LRL = Lower Reporting Limit Cone = Concentration (Totals include 2,3,7,8-substituted isomers) 1 = Interference EMPC = Estimated Maximum Possible Concentration E = PCDE Interference A = Detection Limit based on signal-to-noise measurement S = Saturated signal J = Concentration detected is below the calibration range ND = Not Detected B = Less than 10 times higher than method blank level NA = Not Applicable P = Recovery outside of target range NC = Not Calculated Nn = Value obtained from additional analysis ’ = See Discussion Report No.... 02-1055248
1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Ino.
CONFIDENTIAL, CITY_21MC100_003431973
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000240218
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000240234
Laboratory analysis report from Pace Analytical for NYC WTC material, 2008 protective-order context.
3 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240225
Laboratory analysis report; NYC-WTC sample; confidential order.
3 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240204
Laboratory analysis results; NYC-WTC sample; confidential order.
4 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240179
Lab analysis report; NYC World Trade Center sample cited; Appendix B.
4 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240188
Laboratory analysis report; NYC-WTC sample with protective order.
3 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178033
Confidential laboratory analysis report appendix from [name] Services regarding World Trade Center samples.
3 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240793
Lab report with CONFIDENTIAL label and protective order reference; Appendix B.
3 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326680
Lab report header and CITY_21MC100_012156707; NYC-WTC_000326680.
4 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240753
Appendix B of Pace lab report; NYC-WTC samples; confidentiality.
4 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250163
Appendix B: Report of laboratory analysis for NYC project; sample IDs documented.
3 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250154
Lab analysis report for NYC project; NYC-WTC sample shows confidentiality tag.
3 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240813
Appendix B and lab results; confidential under protective order; NYC-WTC file.
4 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000240234
Laboratory analysis report from Pace Analytical for NYC WTC material, 2008 protective-order context.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177785
Laboratory report for PCDDs and PCDFs analysis of wipe samples from PS234M collected March 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177798
Laboratory report presenting analysis results for polychlorinated dibenzo-p-dioxins and dibenzofurans from a wipe sample collected at PS 234M.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240242
Determination of dioxin and furan levels prepared for ATC Associates in New York, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314005
Pace Analytical lab report for wipe sample U20425A, dated 04/25/2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000194774
Laboratory analysis report for dioxins and dibenzofurans in a wipe sample collected at PS 89M on February 7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000240234
Laboratory analysis report from Pace Analytical for NYC WTC material, 2008 protective-order context.
Similar indexed content
Laboratory analysis report; NYC-WTC sample; confidential order.
Similar indexed content
Laboratory analysis results; NYC-WTC sample; confidential order.
Similar indexed content
NYC-WTC_000240179
Lab analysis report; NYC World Trade Center sample cited; Appendix B.
Similar indexed content
NYC-WTC_000240188
Laboratory analysis report; NYC-WTC sample with protective order.
Similar indexed content