JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 ’I Phone: (212) 420-8119 Fax. (212) 420-6092 Project No.- 01-2089 Rose Associates ELAP Lab Code. 11029 Analyte. FIBERS 200 Madison Avenue NIOSH and AIHA Lab Code 100273 Date Received 10/5/2001 New York, NY 10016-3901 NVLAP Lab Code 101953 Date Analyzed- 10/5/2001 Batch#: 0110A688 SUMMARY OF ANALYTICAL RESULTS Site; 21 West Street, New York, NY

SAMPLE # COLLECTED DESCRIPTION I LOCATION TIME(ililn) VOLUME(I) FIB/FIELD RESULTS(f/cc) LAB#

019 Ambient/ Apt. 3H/ Back Bedroom 120 1837.8 2/100 0001 05-October A 6953

020 Ambient/ Apt. 3H/ Hall By Bathroom 120 1837 8 3/100 0^ 05-October A 6954

021 Ambient/Apt. 17H 120 1837.8 4/100 0.001 05-October A 6955

022 Ambient/Apt. 17H 120 1837.8 3/100 0.001 05-October A 6956

023 Ambient/ PHC/ 2nd Level Bedroom 120 1837 8 2/100 0.001 05-October A 6957

024 Ambient/ PHC/ 2nd Level Bathroom Area 120 1837.8 2/100 0.001 05-October A 6958

Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/100 Fields VOID1 = H.C P. ( High Concentration of Particles) Positive Phase Contrast Microscopy (PCM) VOID2 = Overloaded Method of Sample Preparation and Analysis All samples analyzed in accordance with the NIOSH 7400 Method using "A” Counting Rules Issue 2, August 1994

Instrumentation Olympus PCM Model BH-2 with Walton-Beckett Graticule (tOOum field diameter) Laboratory Director Report Date: October 6. 2001 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400 Among other limitations, this method gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs beyond the above Page 6 of 7

CITY_21MC100_002388984

NYC-WTC_000390900

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390900Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →