NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
► Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2089
Rose Associates ELAP Lab Code: 11029 Analyte: FIBERS
200 Madison Avenue NIOSH and AlHA Lab Code: 100273 Date Received: 10/5/2001
New York, NY 10016-3901 NVLAP Lab Code: 101953 Date Analyzed: 10/5/2001
Batch #: 011OA688
SUMMARY OF ANALYTICAL RESULTS
Site:
L 21 West Street, New York, NY
SAMPLE #
COLLECTED DESCRIPTION I LOCATION TIME(min) VOLUME(I) FIB/FIELD RESULTS(f/cc)
LAB #
013 Ambient/ 5th Floor Corridor 120 1837.8 2/100 0.001
05-October
A 6947
014 Ambient/ 5th Floor Corridor 120 1837.8 2/100 0.001
05-October
A 6948
015 Ambient/ Lobby Next to Mail Room 120 1837.8 4/100 0.001
05-October
A 6949
016 Ambient/ Lobby Gym 120 1837.8 3/100 0.001
05-October
A 6950
017 Ambient/ Apt. 11C/ Hallway By Bathroom 120 1837.8 2/100 0.001
05-October
A 6951
018 Ambient/ Apt. 11C/ Children Room 120 1837.8 4/100 0.001
05-October
A 6952
Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/ 100 Fields
Positive Phase Contrast Microscopy (PCM) VOID1 = H.C.P. ( High Concentration of Particles)
VOID2 = Overloaded
Method of Sample Preparation and Analysis:
All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules, Issue 2, August 1994
Instrumentation:
l~ularTl wal~a
Olympus PCM Model BH-2 with Walton Beckett Graticule (I 00um field diameter).
Laboratory Director
Report Date: October 6, 2001
JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this
method gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of
JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client
agrees to seek no costs beyond the above.
Page 5 of 7
NYC-WTC 000094667