JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Project No.: 01-2089002 Rose Associates Inc. ELAP Lab Code- 11029 Analyte: FIBERS 200 Madison Ave. Sth Floor NIOSH and AIHA Lab Code- 100273 Date Received 10/15/01 New York, NY 10016 NVLAP Lab Code 101953 Date Analyzed 10/16/01 Batch#; 0110A741 SUMMARY OF ANALYTICAL RESULTS Site: 21 West Street, New York, NY

SAMPLE # COLLECTED DESCRIPTION I LOCATION TIME(min) VOLUME(I) FIB/FIELD RESULTS(f/cc) LAB#

007 Ambient/ 15th Floor/ Corridor/At the North 90 1385 5/100 0.002 12-October Section of the Corridor A 7519

008 Ambient/1 Sth Floor/ At the South Section of the 90 1385 6/100 0.002 12-October Corridor A 7520

009 Ambient/ 10th Floor/ At the North Section of the 90 1385 7/100 0.002 12-October Hallway A 7521

010 Ambient/10th Floor/ At the South Section of the 90 1385 6/100 0.002 12-October Hallway A 7522

Oil Ambient/ 9th Floor/ At the North Section of the 90 1385 6/100 0,002 12-October Hallway A 7523

012 Ambient/ 9th Floor/ At the South Section of the 90 1385 5/100 0,002 12-October Hallway A 7524

Sample Analysis by <LOD = Less than limit of detection which is 5 5 Fibers/100 Fields Positive Phase Contrast Microscopy (PCM) VOID1 = H.C.P. { High Concentration of Particles) VOID2 = Overloaded Method of Sample Preparation and Analysis. All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules Issue 2, August 1994

Instrumentation Olympus PCM Model BH-2 with Walton-Beckett Graticule (tOOum field diameter) Guiam Mlachhiwaia Laboratory Director Report Date: October 16, 2001 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400 Among other limitations, this meth gives only an index of airborne fibersand provides only an estimate of asbestos concentration Any and all claims arising outof JLC'sanalysi these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs b the above Page 2 of 5

CITY_21MC1OO_OO2388974

NYC-WTC_000390891

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390891Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →