NYC 9/11 Public Portal Document
D m
U'u ' - 5 ' “.«b LNVlKUNntNlPL-N* NU. ^1^Z13/8U8
AASERViPonmental, Inc
£rv;ron~e-:ta’; rs'j'tcnis
Washingtor,. DC
643 ISisiiHiin Lane
Hockvili;. MQ2ne5C-’.3aS
13011 254-3.71 > October 31, 2001
(30)1 794.3217 FAX
New York. NV Mr. Richard Rubel
72 Mftiii'o- Avc.ije
Wew YC.-t. NY >0613.8731
Cedar Management Coip.
(212) 213-«73(; 20 Vesey Street
(212; 213-7808 fAX
New York, NY 10007
tBUimote. MO
225 Noun Caivkti Sneei
HSitimoro MD 21202
Re: Air and Wipe Sampling
Mall SioB- MD4 30'’■■ /•:■
(410) 505-152-
(110) 605-8378 Fax
Dear Mr. Rubel:
Arlington. VA
2345 Crvsrai Cnve
On October 25, 2001, A AS Environmental, Inc., represented by Vincent Hetsberger,
Suite 'GUO collected ambient air samples at five locations at 20 Vesey Street for testing for the
Ar'kijM", VA 22'2a?-48C-
(703) 769-0295
presence of airborne asbestos fibers. The five locations were the Suite 200, Suite 300,
(7031 /S5-13G3 FAX 7“* Floor Law Office, Lobby and Room 610. Samples were collected by high volume
Hinitkurg. PA air samplers at approximately 15 liters per minute (Ipm) and analyzed by an
200 Souiti 18th Svse; independent laboratory by Phase Contrast Microscopy (PCM).
Harr.sijirg, i-k >7124-1205
(717! ?34-3S2e
(71; 238-2300 fAX All five samples indicated levels of asbestos well below the clearance criteria for
reoccupancy following an abatement project of 0.01 fibers per cubic centimeter (f/cc)
established by the New York City Department of Environmental Protection and the
New York State Department of Labor. Copies of the laboratory results are attached
for your records.
A total of two (2) dust wipe samples were collected at locations specified by Cedar
Management Corp. All samples were delivered to an independent laboratory and
analyzed by Polarized Light Microscopy (PLM). The laboratory analysis indicate
that the dust wipe samples resulted in no visible asbestos (NVA).
Area air monitoring for nuisance dust performed in the Room 610 and Suite 300 resulted in
8-hour time weighted averages (TWA) of <0.03 milligrams per cubic meter (ing/mO and
0.07 (mg/m’) respectively The results are well below the OSHA Permissible Exposure
Limit (PET.) for total nuisance dust in air of 15 mg/m'.
Please see the attached sample results. If you have anv questions or concerns, please
call me at (212) 213-8700.
Sincerely.
Dodg Gloric
Project Manager
Health anh Safety
investijatiorj arif! Audits
Envifonmenta; Site Assessments
Rernetiation Design and Managemer;
A Comohijgied Sngineeiiiis Atnhme
CITY_21MC1OO_OO2388298
NYC-WTC_000390435
OCR can misread numbers and units. Confirm readings against the page image before using them.