Environmental testing results memo, Oct 2001

Machine-extracted title · confidence 42%

PSI testing at BMCC facility; visual inspection and sampling plan; results below guideline levels.

NYC-WTC_000390165–000390167
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sample Location Result A-25 South Bldg., 3** Floor, outside Room S330 32 s/mm2 A.47 South Bldg., Theater 16s/mm2

Asbestos in Dust PSI visually observed dust accumulations on surfaces within the Gymnasium (north building) and Theater 1 (south building). The presence of dust is likely due to usage of these areas by cmcrgency/rcscue workers.

PSI collected 3 microvacuum samples within each of these areas for a total of 6 samples. Dust samples were collected by microvacuum and analyzed by Transmission Electron Microscopy in accordance with ASTM Method D5755-95. TEM has the ability to distinguish between asbestos Structures and non-asbestos structures. The subject ASTM methodology reports analytical results in ■ asbestos structure concentration per square centimeter of surface area (s/cm2). The publication ‘‘Advances in Environmental Measurement Methods for Asbestos” prepared by the ASTM Committee D-22 on Sampling Analysis of Atmospheres in conjunction with the Environmenul Information Association references the following guidelines pertaining to asbestos in surface dust. <1,000 s/cm2 indicates low level >10,000 s/cm2 indicates above general background level >100,000 s/cm2 indicates high level

Asbestos structures were detected in 2 of 6 samples as shown below. Although asbestos structures were detected, results indicate low level concentrations ranging from well below to slightly above the stated criteria of 1,000 s/cm2. As a precautionary measure, PSI recommends the surfaces in the gymnasium and theater be cleaned via wet wiping and/or HEPA vacuuming,

Sample Location Result MV-02 North Bldg., Gymnasium Floor, Center 315.438 6/cm2 MV-05 j South Bldg., Theater 1, Center 1.051.850 s/cm2

In addition to raicrovflcuum samples, surface wipe samples were collected within the Gymnasium (north building) and Theater 1 (south building), PSI collected 3 wipe samples within each of these areas for a total of 6 samples. Qualitative analysis was performed by Polarized Light Microscopy (PLM) to determine the presence or absence of asbestos fibers. No asbestos fibers were detected in any of the samples.

Lead Wipe Sampling Surface wipe samples were collected within the Gymnasium (north building) and Theater 1 (south building). PSI collected 3 wipe samples within each of these areas for a total of 6 samples. Surface wipe samples were analyzed by EPA Method S W846-7420 and demonstrate concentrations below the EPA Leaded Dust Level Criteria of 40 micrograms per square foot.

CITY_21MC100_008854609

NYC-WTC_000390166

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390166Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →