NYC 9/11 Public Portal Document
Result
A-25 South Bldg., 3' Floor, outside
A-47 South Bldg., Theater
Asbestos in Dust
Gymnasium (north building) and
PSI visually observed dust accumulations on surfaces within the
Theater 1 (south building). The presence of dust is likely due to usage of these areas by--
emergency/rescue workers.
6 samples. Dust
PSI collected 3 microvacuum samples within each of these areas for a total of
samples were collected by microvacuum and analyzed by Transmission Electron Microscopy in
accordance with ASTM Method D5755-95. TEM has the ability to distinguish between asbestos
analytical results
structures and non-asbestos structures. The subject ASTM methodology reports in
asbestos structure concentration per square centimeter of surface area (s/cm2). The publication
"Advances in Environmental Measurement Methods for Asbestos' prepared by the ASTM
Committee D-22 on Sampling Analysis of Atmospheres in conjunction with the Environmental
surface dust.
Information Association references the following guidelines pertaining to asbestos in
<1,000 s/cm2 indicates low level
>10.000 s/cm2 indicates above general background level
>100,000 s/crn2 indicates high level
Asbestos strictures were detected in 2 of 6 samples as shown below. Although asbestos structures
the
were detected, results indicate low level concentrations ranging from well below to slightly above
stated criteria of 1,000 s/cm2. As a precautionary measure, PSI recommends the surfaces In the
gymnasium and theater be cleaned via wet wiping and/or FIEPA vacuuming.
pie Location Result
-02 North Bldg., Gymnasium Floor, Center 315.438
-05 South Bldg., Theater 1, Center 1,051.8:
In addition to microvacuum samples, surface wipe samples were collected within
the Gymnasium
(north building) and Theater I (south building). PSI collected 3 wipe samples within each of these
areas for a total of 6 samples. Qualitative analysis was performed by Polarized Light Microscopy
were detected in
(PLM) to determine the presence or absence of asbestos fibers. o asbestos fibers
any of the samples.
Lead Wipe Samplina
Surface wipe samples were collected within the Gymnasium (north building) and Theater 1 (south
samples. Surface
building). PSI collected 3 wipe samples within each of these areas for a total of 6
concentrations below the
wipe samples were analyzed by EPA Method SW846-7420 and demonstrate
EPA Leaded Dust Level Criteria of 40 micrograms per square foot.
NYC-WTC 000106378