Environmental Protection Agency Pt. 763, Subpt. E, App. A operations are within acceptable limits. In develop within the sampling and analysis op­ this way. the quality of the data is defined erations. A description of these quality con- and the results are of known value. These troVquality assurance procedures is summa­ checks and tests also provide timely and spe­ rized in the following Table III: cific warning of any problems which might

TABLE III—SUMMARY OF LABORATORY DATA QUALITY OBJECTIVES

Confonnance Unlt.QpCratiQn OCCheck Frequency Expectation

Sample receiving Review of receiving repon Each sample 95% complete Sample custody Review of chain-of-custody record Each sample 95% complete Sample preparation Supplies and reagents On receipt Meet specs, or reject Grid opening size 20 openings/20 grids/lot 100% of 10(X) or 1 openingZsample Special clean area monitoring After cleaning or service Meet specs or reclean Laboratory blank 1 per prep series or 10% Meet specs, or reanalyze series Plasma etch blank 1 per 20 samples 75% Multiple preps (3 per sample) Each sample One with cover of 15 compleu grid sqs. Sample analysis System check Each day Each day Alignment check Each day Each day Magnification calibration with low and high Each month or after service 95% standards ED calibraiion by gold standard Weekly 95% EDS calibration by copper line Daily 95% Perfofmstce check Laboralory blank (measure of cleanliness) Prq) 1 per scries or 10% Meet specs or read 1 per 25 samples reanalyze series Replicate counting (measure of precision) 1 per 100 samites 1.5 X Poisson Std. Dev. Chiplicate analysis (measure of reproducibility) I per 100 samples 2 X Poisson Std. Dev. Known samples of typical materials Training and for com­ 1(X)% (working standards) parison with unknowns Analysis ofNBS SRM 1876 and/or RM 8410 1 per analyst per year 1.5 X Poisson Std. E>cv. (measure of accuracy and comparability) Data entry review (data validation and measure Each sample 95% of completeness) Record and verify ID electron diffraction pattern 1 per 5 samples 80% accuracy of structure Calculations and Hand calculation of automated data reduction 1 per 100 samples 85% data reduction piQcctbre or independent recalculation erf hand- calculated data

1. When the samples arrive at the labora­ 3. Conduct all sample preparation in a tory, check the samples and documentation clean room environment monitored by lab­ for completeness and requirements before oratory blanks. Testing with blanks must initiating the analysis. also be done after cleaning or servicing the 2. Check all laboratory reagents and sup­ room. plies for acceptable asbestos background lev­ 4. Prepare multiple grids of each sample. els.

679

NYC-WTC_000389988

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000389988Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →