NYC-WTC_000363392
ATC TEM dust method practice document referencing AHERA/ASTM 5755.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
NYC-WTC_000389978–000390013OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Pt. 763, Subpt. E, App. A 40 CFR Ch. I (7-J-OO Edition) 5. Provide laboratory blanks with each “Proposed Analytical Method for Determina sample batch. Maintain a cumulative aver tion of Asbestos in Air . ” age of these results. If there are more than 53 8. Chatfield. E.J., Chatfield Tech. Cons., fibers/mm per 10 200-mesh grid openings, the Ltd., Clark, T., PEI Assoc., "Standard Oper system must be checked for possible sources ating Procedure for Determination of Air of contamination. borne Asbestos Fibers by Transmission Elec 6. Perform a system check on the trans tron Microscopy Using Polycarbonate Mem mission electron microscope daily. brane Filters,” WERL SOP 87-1, March 5, 7. Make periodic performance checks of 1987. magnification, electron diffraction and en 9. NIOSH Method 7402 for Asbestos Fibers. ergy dispersive X-ray systems as set forth in 12-11-86 Draft. Table III under Unit II.I. 10. Yamate. G.. Agarwall. S.C.. Gibbons. 8. Ensure qualified operator performance R.D.. IIT Research Institute. “Methodology by evaluation of replicate analysis and for the Measurement of Airborne Asbestos by standard sample comparisons as set forth in Electron Microscopy.” Draft report. USEPA Table III under Unit II.I. Contract 68-02-3266. July 1984. 9. Validate all data entries. 11. “Guidance to the Preparation of Qual 10. Recalculate a percentage of all com ity Assurance Project Plans.” USEPA. Office putations and automatic data reduction of Pollution Prevention and Toxics. 1984. steps as specified in Table III under Unit II.I. III. IVonmandatoiy Transmission Electron 11. Record an electron diffraction pattern Microscopy Method of one asbestos structure from every five samples that contain asbestos. Verify the A. Definitions of Terms identification of the pattern by measure ment or comparison of the pattern with pat 1. Analytical sensitivity—Airborne asbestos terns collected from standards under the concentration represented by each fiber same conditions. The records must also dem counted under the electron microscope. It is onstrate that the identification of the pat determined by the air volume collected and the proportion of the filter examined. This tern has been verified by a qualified indi method requires that the analytical sensi vidual and that the operator who made the tivity be no greater than 0.005 s/cm’. identification is maintaining at least an 80 2. Asbestiform—A specific type of mineral percent correct visual identification based fibrosity in which the fibers and fibrils pos on his measured patterns. sess high tensile strength and flexibility. 12. Appropriate logs or records must be 3. Aspect ratio—A ratio of the length to the maintained by the analytical laboratory width of a particle. Minimum aspect ratio as verifying that It Is in compliance with the defined by this method is equal to or greater mandatory quality assurance procedures. than 5:1. J. References 4. Bundle—A structure composed of three or more fibers in a parallel arrangement For additional background information on with each fiber closer than one fiber diame this method, the following references should ter. be consulted. 5. Clean area—A controlled environment 1. “Guidance for Controlling Asbestos-Con which is maintained and monitored to assure taining Materials In Buildings.” EPA 560/5- a low probability of asbestos contamination 85-024. June 1985. to materials in that space. Clean areas used 2. “Measuring Airborne Asbestos Following in this method have HEPA filtered air under an Abatement Action.” USEPA. Office of positive pressure and are capable of sus Pollution Prevention and Toxics. EPA 600/4- tained operation with an open laboratory 85-049. 1985. blank which on subsequent analysis has an 3. Small. John and E. Steel. Asbestos average of less than 18 structures/mm^ In an Standards: Materials and Analytical Meth area of 0.057 mm^ (nominally 10 200 mesh grid ods. N.B.S. Special Publication 619. 1982. openings) and a maximum of 53 structures/ 4. Campbell. W.J.. R.L. Blake. L.L. Brown. mm2 for no more than one single preparation E.E. Cather, and J.J. Sjoberg. Selected Sili for that same area. cate Minerals and Their Asbestlform Vari 6. Cluster—A structure with fibers In a ran eties. Information Circular 8751. U.S. Bureau dom arrangement such that all fibers are of Mines. 1977. intermixed and no single fiber is isolated 5. Quality Assurance Handbook for Air Pol from the group. Groupings must have more lution Measurement System. Ambient Air than two intersections. Methods. EPA 600/4-77-027a. USEPA. Office of 7. ED—Electron diffraction. Research and Development. 1977. 8. EDXA—Energy dispersive X-ray anal 6. Method 2A: Direct Measurement of Gas ysis. Volume through Pipes and Small Ducts. 40 9. Fiber—A structure greater than or equal CFR Part 60 Appendix A. to 0.5 pm in length with an aspect ratio 7. Burdette. G.J.. Health & Safety Exec. (length to width) of 5:1 or greater and having Research & Lab. Services Div.. London. substantially parallel sides.
680
NYC-WTC_000389989
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000363392
ATC TEM dust method practice document referencing AHERA/ASTM 5755.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
18 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
18 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
18 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
18 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
18 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
18 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
18 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
17 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
18 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318556
Information sheet on asbestos design and analysis standard D5755, undated revision notes.
9 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149346
A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
14 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443893
Chain-of-custody appendix with Part 763 asbestos standards and definitions.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
Similar indexed content
NYC-WTC_000139257
DEP official requests final review of the latest air monitoring Scope of Work to conclude negotiations.
Similar indexed content
NYC-WTC_000363392
ATC TEM dust method practice document referencing AHERA/ASTM 5755.
Similar indexed content
NYC-WTC_000318556
Information sheet on asbestos design and analysis standard D5755, undated revision notes.
Similar indexed content
NYC-WTC_000149346
A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
Similar indexed content