NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

PLM Bulk Asbestos, Area #5, Sep 2001

Machine-extracted title · confidence 40%

Bulk asbestos analysis results for Area #5 samples from Consulting LLC.

NYC-WTC_000389328–000389329
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

^7 P 117 EAST 30TH STREET NEW YORK, NY 10016 FVIJ.SEHVJCE ENVfKO.WMENTAt. LAbOR.A7OE}ES TEL: (212) 679-8600 • FAX; (212) 679-9392

PLM Bulk Asbestos Report Total Safety Consulting, LLC Date Received 09/19/2001 SciLabJobNo. 201092439 Attn: Fred Milteer Date Examined 09/20/2001 P.O.# Turner Construction 6 Highland Avenue ELAP Number 11480 Page 1 of 1 Staten Island, NY 10301 RE: Turner Construction ; Area #5

Client No. / IIGA Lab No. Asbestos Present Total % Asbestos FM091901-001A 201092439-01 Fes <1.% 1 Location: Fallout Insulation Material Debris

Description: Beige, Homogeneous, Debris Asbestos Types: Chrysotile <1. % Other Material: Cellulose 10.%. Fibrous glass 30. %, Non-fibrous >59. %

FM09190I-001B 201092439-02 <1.% 1 Location: Fallout Insulation Material Debris

Description: Beige, Hontogeneous, Debris Asbestos Types: Chrysotile <1. % Other Material: Cellulose 7.%, Fibrous glass 35.%, Non-fibrous >57.%

FM091901-001C 201092439-03 Fes <1.% 1 Location: Fallout Insulation Material Debris

Description: Beige, Homogeneous, Debris Asbestos Types: Chrysotile <1. % Other Material; Cellulose 20. %, Fibrous glass 35. %, Non-fibrous >44. %

Reoortine Notes: , ./? Analyzed by: Ivan Recalde\NV^6^_^^Jl^^ *NAD/NSD = no asbestos dented; N.A = not analyzed; NA/PS = not analyzed / positive stop; PLM Bulk Asbestos Analysis by EPA 600/M4-82-020 per 40 CFR 763 (NVLAP Lab #200346-0) and ELAP PLM Analysis Protocol 198.1 for New York samples (NYSDOH ELAP Lab # 11480); Note: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. TEM is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing in New York State (also see EPA Advisory for floor tile, FR 59, 146, 38970, 8/1/94). National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in fuj/w'ithout the appioval of the laboratory. This PLM report relates ONLY to the items tested. AIHA# 102843; VT Certs A

Reviewed By:.

CITY_21MC100_002840219

NYC-WTC_000389328

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000389328Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →