MMVF sampling guidance, EMSL

Machine-extracted title · confidence 60%

Discussion of MMVF sampling, microscopy methods, and source tracing for contamination.

NYC-WTC_000389091
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Full Particle ID incorporates physical testing with Polarized Light Microscopy (PLM), Scaiming Electron Microscopy (SEM), Transmission Electron Microscopy (TEM) and X-Ray Diffraction (XRD) to identify nearly all particles from cotton fibers, dander and dust mites to unusual materials such as carbon black, metal oxides and minerals. This analysis is best performed in conjunction with Air-O-Cell cassettes or other media to identify any fungal allergens. This method is the perfect procedure for initial site surveys where Indoor Air Quality is in question.

Sampling of bulk materials is typically performed by the glove bag technique. Dust is commonly collected by micro- vacuuming or wipe sampling with a 4x4 inch piece of baby wipe, (no aloe or cleaners). Air sampling is performed using a 0.1 pm Polycarbonate filter and an Air-O-Cell cassette.

0.1 |im Polycarbonate filter 10-15 1pm ( volume of 1,500 - 3,000 liters ) Air-O-Cell Cassette 10-15 1pm ( volume of 75 - 200 liters)

When “Site Standards” are taken of the various suspect materials through out the job site, the particles found in the samples can be matched to the Site Standards. This can pin point the actual source of the contamination. When air sampling for fungi, a sample should be acquired from outside the building preferably near a fresh air intake. This will act as a “Baseline” for the fungi concentrations found in the sampling area.

Elemental Composition of Particulate

SI 2000

SI 1500 ■aT

im I 1000 _________ Cl______ ______________________________________________

b' te JM L JuJl 500

..hi ’ « 8 K«Vs I 8 I 8 8 U U■6767I U g U I I“■ ills

EDX of sample containing Halite (natural salt), Gypsum and Kaolinite (clay) XRD of Zinc Sulfate Paint Pigment from construction dust

Matrix : Bulk, Dust, Air Pricing for Full Particle Identification:

1 day 2 day 3 day 4 day 5 day 6-1- days

Air Samples $500 $400 $350 $300 $265 $225 Dust & Bulk $550 $450 $375 $330 $300 $275

Moth Scale

EMSL Analytical, Inc. - 107 Haddon Avenue, Westmont, NJ 08108 1-800-220-3675 Ext. 1213

CITY_21MC100_003835416

NYC-WTC_000389091

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000389091Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →