NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 7 pages

Asbestos investigation, Bronx Zoo Animal Hospital, 1997

Machine-extracted title · confidence 42%

Draft asbestos investigation report for roof restorations at Bronx Zoo Animal Hospital, 2300 Southern Blvd, Bronx, NY.

NYC-WTC_000387859–000387865
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I

Asbestos Investigation- Bronx Zoo Animal Hospital Work Order Letter No -WP1 Wanen & Panzer Engineers. P C 18 January 1999

3 0 SUMMARY OF FINDINGS

During the investigation, observations were made of the construction, approximate size, and condition of the structure

During the investigation, W & P observed the following suspect asbestos containing building materials

Lower Roof (Flat Roof)

• Walking Pad • Coping Stone material • Coping Stone Mastic • Cap Flashing • Mastic under Cap Flashing • Flashing on fiberglass insulation on HVAC duct lines • Roof Membrane • Light Wt Concrete Deck • Patch material near HVAC units • Brick Mortar • Brick Joint Mastic

Upper Roof (Pitch Metal Roof) • Mastic around ice stopping metal poles • Mastic between metal sheets joints • Felt roofing material on partial flat roof in rear • Mastic between metal joints • Coping Stone Mastic

A total of 45 bulk samples were collected from these materials in accordance with required sampling protocols These samples were analyzed utilizing Polarized Light Microscopy (PLM) at WKP Laboratories, Inc located in New York, NY TEM analysis was performed by Scientific Laboratories located in New York NY

The laboratory analysis performed on the samples collected of suspect materials determined that the following material is asbestos containing material

• Flashing on fiberglass insulation on HVAC duct lines

All other suspect materials listed above are non-asbestos containing materials and can be removed and disposed of as normal construction debris Please refer to Appendix A for sampling location and results

The survey was limited to exposed surfaces only Probe of concealed spaces and metal/wood doors was not performed at the time of survey

Page 5

NYC-WTC_000387863

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000387863Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →