Asbestos Investigation- Bronx Zoo Animal Hospital Work Order Letter No -WPl Warren & Panzer Engineers, P C________________ 18Jariuarv 1999

SAMPLE BULK SAMPLE MATERIAL BULK SAMPLE LABORAT IDENTIFICAT DESCRIPTION LOCATION ORY ION ANALYSIS NUMBER RESULTS 821 18 01 13-03 Felt Roofing Material Upper Roof Partial Flat Roof NAD (in rear) 821 18 01-14-01 Mastic between metal Joints Upper Roof-Pitch Metal Roof NAD 821 18 01-14-02 Mastic between metal Joints Upper Roof Pitch Metal Roof NAD 821 18 01-14-03 Mastic between metal Joints Upper Roof-Pitch Metal Roof NAD 821 18 01-15-01 Coping stone Mastic Upper Roof Pitch Metal Roof NAD

821 18 01-15-02 Coping stone Mastic Upper Roof-Pitch Metal Roof NAD 821 18 01-15-03 Copmg stone Mastic Upper Roof Pitch Metal Roof NAD NA Not Analyzed (Each homogeneous material was analyzed unit first positive result) NAD No Asbestos Detected

Polarized Light Microscopy (PLM) analysis was performed by WKP Laboratories Inc located in New York, NY, NVLAP Certification # 101950 0 Transmitting Electron Microscopy (TEM) analysis was performed by Scientific Laboratories Inc located in New York NY NVLAP Certification # 101646-0

BOLD denotes positive bulk sampling result

Page 9

NYC-WTC_000387867

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000387867Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000387859

Draft asbestos investigation report for roof restorations at Bronx Zoo Animal Hospital, 2300 Southern Blvd, Bronx, NY.

Similar indexed content

Compare copies and versions →