NYC-WTC_000357923
Cleaning guidelines and asbestos exposure control measures for Three World Financial Center floors.
2 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Guidance on asbestos-related cleaning controls and PPE for building cleaning crews.
NYC-WTC_000387745OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
<6^/os CSzIzaxJ
THREE WORLD FINANCIAL CENTER
GENERAL CLEANING: 30*”-sr* FLOORS
Definition: Light accumulation of visible dust present. Does not require a Notice of Asbestos Abatement as a regulated area, following NYC Title 15, Chapter rules, per the NYCDEP memorandum dated 9/26/01, if dust is not asbestos-containing.
Minimum Requirements:
• All cleaning personnel to have pulmonary function and respirator fit tests, prior to assignment to work areas. • All cleaning personnel to wear one-half face respirators, with HEPA cartridges. • Asbestos exposure assessments to be performed, on a minimum of 20% of the cleaning work force, by monitoring personal breathing zone to measure eight-hour time weighted average exposure. • Personal hygiene facilities shall be provided. • HEP A-filter equipped vacuum and wet wipe all surfaces,nncluding above ceilings A • Final airborne asbestos clearance shall be by Transmission Electron Microscopy (TEM), in accordance with the AHERA standard, prior to occupancy by unprotected workers.
RECOMMENDED CONTROLS TO PROTECT WORKERS AND PROPERTY
No HVAC equipment to be tumed-on from the ground floor to the 52'“' floor until return air . plenums, ductwork, louvers, filters, and equipment are inspected, assessed, and cleaned, as I’i’i*'** ' required. • Erect isolation barriers comprised of polyethylene sheeting and wood studs on each floor from 3"* floor to the 9^’’ floor and from the 17*’’ floor to the 26*’’ floor, in the SE comer, at the interior side of the existing or planned demising wall dimensions. Install crossed-flapped doorways and place “tacky” mats at each access point through the isolation barriers. This work can be completed before the demising walls are erected on floors 3-9. (Note: As of 10/25, demising walls have been erected on floors 19-26, only. 17*’’ and 18*'' floor demising walls to be completed o/a 10/31.) • Erect isolation barriers comprised of polyethylene sheeting and wood studs on each floor from 3*’’ floor to the 9*’’ floor and from the 17“* floor to the 26*’’ floor, along the access path from the freight elevators to the existing or planned demising walls. • Keep all stairwell doors closed from the lobby floor to the 26*’’ floor. Triple, cross-flap each of these stairwell doorways with polyethylene sheeting. HEPA-vacuum and wet-wipe stairwells after “sealing” doorways. Perform final clearance by TEM. Place “tacky” mats at each doorway. Restrict floor access to use by stairwell “R”, only. • Erect single-stage containment comprised of polyethylene sheeting and wood studs at each freight elevator, on every floor to be accessed by the freight elevators from floors 3-26. Place “tacky” mats at each freight elevator containment entrance. • Install masonite board and polyethylene sheeting floor protection on all hardwood or tile floors to be used to access SE comer during demolition. Remove and properly dispose of carpet on floors to be used to access SE comer during demolition. Restrict access to any other unprotected floor areas by temporary plywood barriers. Install plywood protection for hardwood doors and frames, office wall glass, and corridor walls along the access path from the freight elevators to the existing or planned demising walls.
Prepared by; Jeffrey A. Boggs, CHMM 10/29/01 Director of Environmental Services, EMG Page 1 of 1
CITY_21MC100_003832407
NYC-WTC_000387745
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000357923
Cleaning guidelines and asbestos exposure control measures for Three World Financial Center floors.
2 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220308
Memo outlining general cleaning protocols, respiratory protection requirements, and exposure monitoring procedures for dust at Three World Financial Center.
2 shared non-person entities · 1 shared topics · similarity 0.903
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104853
Facsimile cover sheet transmitting documents regarding environmental work at 102 Greenwich Street.
2 shared non-person entities · 1 shared topics · similarity 0.904
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448332
DOL 12 NYCRR Part 56 reference and regulatory context for asbestos.
2 shared non-person entities · 1 shared topics · similarity 0.903
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
2 shared non-person entities · 1 shared topics · similarity 0.903
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
2 shared non-person entities · 1 shared topics · similarity 0.902
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441450
Asbestos standards reference page from NY Department of Labor materials.
2 shared non-person entities · 1 shared topics · similarity 0.902
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451646
Asbestos Part 56 inspection reference document, NYC.
2 shared non-person entities · 1 shared topics · similarity 0.902
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000233286
Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.
2 shared non-person entities · 1 shared topics · similarity 0.902
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437549
Asbestos chain-of-custody record for NYC WTC project, including state code reference.
2 shared non-person entities · 1 shared topics · similarity 0.901
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446470
State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.
2 shared non-person entities · 1 shared topics · similarity 0.901
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443384
State regulation reference: Part 56 of Title 12 NYCRR, asbestos compliance document.
2 shared non-person entities · 1 shared topics · similarity 0.901
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000357923
Cleaning guidelines and asbestos exposure control measures for Three World Financial Center floors.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000364399
Report of bulk sample collection at 100 Church Street for WTC-related work.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000124241
Letter from ATC Associates regarding confirmatory asbestos bulk sampling conducted on the roofs of 99 Church Street.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411802
COSH-related NYC RO regulatory chapter on asbestos control.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448332
DOL 12 NYCRR Part 56 reference and regulatory context for asbestos.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000357923
Cleaning guidelines and asbestos exposure control measures for Three World Financial Center floors.
Similar indexed content
Facsimile cover sheet transmitting documents regarding environmental work at 102 Greenwich Street.
Similar indexed content
Memo outlining general cleaning protocols, respiratory protection requirements, and exposure monitoring procedures for dust at Three World Financial Center.
Similar indexed content
NYC-WTC_000448332
DOL 12 NYCRR Part 56 reference and regulatory context for asbestos.
Similar indexed content
NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
Similar indexed content