Environmental dust sampling report, 90 Church Street

Machine-extracted title · confidence 45%

Report detailing sampling on floors 5–12 for NYCHA property at 90 Church Street.

NYC-WTC_000387663–000387669
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Shaun Hession New York City Housing Authority

EMTEQUE November 12, 2001 Page 5

TABLE 2 POLYCYCLIC AROMATIC HYDROCARBONS Sample #/Location Compound(s) Concentration TAGM (ppm) Standard (ppm) PNA-5-02 Chrysene 0.7 0.4 5'^ Floor - South wall toward SW corner (3 offices from end)

Four samples were obtained from each floor with the exception of the 8’^ floor where EMTEQUE obtained five samples. A total of 33 samples were obtained. Based upon EMTEQUE's initial assumption that contamination would be localized to the southwest quadrant, sampling was broken down with four samples from the dirtiest area (southwest corner - one sample), cleanest area (usually the northwest - one sample), and the tapering off areas (two samples).

Detectable levels of silica were observed within all 33 samples. Sample results ranged from 1.1 to 12.0 percent quartz by weight.

Dioxins

Only bulk samples were obtained for analysis for dioxins. Analysis for dioxin was conducted by PSC. One sample was obtained from each of the subject floors that did not have fire damage. One sample was obtained from the eighth floor, two samples from the fifth floor and three samples were taken from the sixth floor. A total of 11 samples were obtained.

All 11 samples obtained revealed detectable levels of dioxin compounds. In order to review the data, EMTEQUE utilized the World Health Organization (WHO) dioxin equivalency factors (1997). These factors are intended to allow correlation from a level of each dioxin compound to the concentration of 2,3,7,8-C14-Dibenzo-p-dioxin (TCDD). 2,3,7,8-TCDD is considered the most hazardous of the dioxin compounds and each of the other dioxin compounds are compared to this toxicity. After correlation with 2.3,7,8- TCDD, the levels are added to generate a total equivalent concentration. This level was then compared to the TAGM standard of 600 parts per trillion (ppt). Sample results from the fire damaged floors, specifically the 5'^ and 6“^ floors were higher in concentration than the levels from the other floors. One sample from each of the fifth and sixth floors were above the TAGM standard. Observed concentrations did not appear completely consistent with the locations of the fires since rnuch higher levels were identified in the two samples away from the fire on the 6''' floor rather than the sample at the fire location. The two samples from the 5'^ floor away from the fire location appeared consistent with the samples away from the fire on the 6'^ floor. A summary of samples above the TAGM standard is listed in Table 3. t

CITY_21MC1OO_OO2363143 NYC-WTC_000387667

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000387667Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →