Mr. Shaun Hession
New York City Housing Authority
O EMTEQUE November 12, 2001
Page 5
TABLE 2
POLYCYCLIC AROMATIC HYDROCARBONS
Sample #/Location Compound(s) Concentration TAGM
(ppm) Standard
(ppm)
PNA-5-02 Chrysene 0.7 0.4
5th Floor — South wall toward
SW corner (3 offices from end)
Four samples were obtained from each floor with the exception of the 8th floor where
EMTEQUE obtained five samples. A total of 33 samples were obtained. Based upon
EMTEQUE's initial assumption that contamination would be localized to the southwest
quadrant, sampling was broken down with four samples from the dirtiest area (southwest
comer — one sample), cleanest area (usually the northwest — one sample), and the
tapering off areas (two samples).
Detectable levels of silica were observed within all 33 samples. Sample results ranged
from 1.1 to 12.0 percent quartz by weight.
Dioxins
Only bulk samples were obtained for analysis for dioxins. Analysis for dioxin was
conducted by PSC. One sample was obtained from each of the subject floors that did
•
not have fire damage. One sample was obtained from the eighth floor, two samples from
the fifth floor and three samples were taken from the sixth floor. A total of 11 samples
were obtained.
All 11 samples obtained revealed detectable levels of dioxin compounds. In order to
review the data, EMTEQUE utilized the World Health Organization (WHO) dioxin
equivalency factors (1997). These factors are intended to allow correlation from a level
of each dioxin compound to the concentration of 2,3,7,8-C14-Dibenzo-p-dioxin (TCDD).
2,3,7,8-TODD is considered the most hazardous of the dioxin compounds and each of
2,3,7,8-
the other dioxin compounds are compared to this toxicity. After correlation with
total equivalent concentration. This level was
TCDD, the levels are added to generate a
600 parts per trillion (ppt). Sample results from
then compared to the TAGM standard of5th 6th
the fire damaged floors, specifically the and floors were higher in concentration
than the levels from the other floors. One sample from each of the fifth and sixth floors
completely
were above the TAGM standard. Observed concentrations did not appear
consistent with the locations of the fires since much higher levels were identified in the
the fire location.
two samples away from the fire on the 6th floor rather than the sample at
The two samples from the 5th floor away from the fire location appeared consistent with
6th TAGM
the samples away from the fire on the floor. A summary of samples above the
standard is listed in Table 3.
•