Mr. Shaun Hession New York City Housing Authority

EMTEQUE November 12, 2001 Page 4

Detectable levels of PCBs were identified in 10 of the 13 samples. Results from the 6'^ floor revealed relatively low levels at the fire location (62 ppb) and below detection level away from the fire. Levels on the 5“'' floor ranged from 150 to 360 ppb near the fire to non-detected away from the fire. Levels on the 8'^ floor ranged from 290 ppb at the fire location to non-detect away from the location. Samples from the remaining floors (without fire damage) ranged from 130 to 1,400 ppb. For comparison purposes, only the sample from the 10“' floor exceeded the TAGM soil cleanup objective (and the USEPA health based standard) of 1 ppm. A summary of samples above the TAGM standard is listed in Table 1.

TABLE 1 POLYCHLORINATED BIPHENYLS Sample ^/Location Compound(s) Concentration TAGM (ppm) Standard (ppm) PCB-10-01 Aroclor 1254 1.4 1 10“' Floor - Southwest corner

Polycyclic Aromatic Hydrocarbons

A mixture of bulk and wipe samples were obtained for analysis for polycyclic aromatic hydrocarbons (PAHs)/polynuclear aromatics (PNAs). Analysis for PAHs was conducted by PSC.

One sample was obtained from each floor with the exception of the 5'*^ and 6'^ floors from which EMTEQUE obtained three samples and the 8'” floor from which two samples were taken. Additional samples were taken from each of the floors and areas that had fire damage. A total of 13 samples were taken for PAHs. This limited sampling was based upon EMTEQUE’s initial assumption that PAHs would not be present within the inspected spaces.

Detectable levels of PAHs were identified in 10 of the 13 samples. Samples among the non-fire damaged floors appeared relatively consistent. All sample results were below the TAGM Soil Cleanup Objective. Sample results from the fire damaged floors also 'appeared relatively consistent though slightly higher in concentration than the levels from the other floors. One sample from the fifth floor, located at a secretary’s desk in the southwest corner, exceeded the TAGM Recommended Soil Cleanup Objective for chrysene. A summary of samples above the TAGM standard is listed in Table 2.

Silica

A mixture of bulk and wipe samples were obtained for analysis for silica. Analysis for silica was conducted by the Rd Lee Group, Inc. (RJ Lee). RJ Lee is an independent Al HA accredited laboratory.

cITY_2IMC10 026 6 2 3 6 3142 NYC-WTC_000387666

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000387666Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →