Table I summary of TEM asbestos results for dust at 100 Church Street.

NYC-WTC_000386259
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Client Name: TRC Environmental Corporation Table I Summary of Transmission Electron Mi moscopy (TEM) Results for Asbestos (ASTM 575S Dust) 35052-0000-00004; New York City Law Department; 100 Church St. s M I Q Surface * Analytical Structure * Analytical Structure Area As xatos Sensitivity Density Sensitivity Density Type ro G) SciLab Client Sampled Dilution Structures on Grid on Grid on Surface on Surface of G) ro Sample # Sample # ( sq. cm > Factor Detected (Str / sq tnm) (Str/sq mm) (Str/sq.cm ) (Str/ sq. cm ) Asbestos 1C0.0 O 01 SPO13O02MVO201 0.040 0 16.6 <16.6 888 <888 NSD Ceiling Tile - Rm 2-34A, North End 02 SP013002MV0202 100.0 0.040 0 16.6 <16.6 888 <888 NSD Ceiling Tile - Rm 2-310, By Door (3’ From Door) 03 SPOI3O02MVO303 100.0 0.040 0 16.6 <16.6 888 <888 NSD Ceiling Tile - Rm 3-323, By Door 04 SP0I3002MV0304 100.0 0.040 0 16.6 <16.6 888 <888 NSD s 05 Ceiling Tile - Riti 3-318, Center Of Rm. SPO13002MVO405 100.0 0.040 0 16.6 <16.6 888 <888 NSD I Tl Ceiling Tile - Rm 4-315, Center Of Rm. n 06 SP0J3002MV0406 Ceiling Tile - Opposite Rm -4-135 100.0 0.040 0 16.6 <16.6 888 <888 NSD s tn 07 SP0J3002MV0507 100.0 0.040 0 16.6 <16.6 888 <888 NSD Ceiling Tile - Rm 5-326, Center 08 SP013002MV0508 100.0 0.040 0 16.6 <16.6 888 <888 NSD Ceiling Tile - Opp. Rni. 5-129 09 SP0I3002MV0609 100.0 0.040 0 16.6 <16.6 888' <888 NSD Ceiling Tile - Rm. 6-31 IP, Nonh End 10 SP0I3002MV0610 100.0 0.040 0 16.6 <16.6 888 <888 NSD Ceiling Tile - Rm 6-310, By Door I 11 SP013002MV2011 100.0 0.040 0 16.6 <16.6 888 <888 NSD Ceiling Tile - Center Of Floor, Diagonal From Emergency Exit A By De dr o 12 SP013002MV20I2 100.0 0.040 0 16.6 <16.6 888 <888 NSD H Ceiling Tile - Mathew Rosenthal's Office § A

13** Blank -J to I cn

I o 14** Blank I w co § o I o * structure density represented by the detection of 1 structure o ** not analyzed -u CO NSD: No Asbestos Structures Detected G) (-O Date: 2/1/02 KJ O Reviewed By: ; Analyzed By; __ \ IS (-O

NYC-WTC_000386259

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386259Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243643

Summary of TEM microscopy results for asbestos (ASTM 5755 dust) from TRC samples.

Similar indexed content

NYC-WTC_000182344

Summary table of transmission electron microscopy results for asbestos dust samples submitted to the New York City Law Department.

Similar indexed content

Compare copies and versions →