Table I
Siininiary of Transmission Electron Microscopy (TEM) Results for Asbestos (ASTM 5755 Dust) 2
I
35052-0000-00002; New York City Law Department; 100 Church Street ro
A
Structure I
Surface * Analytical Structure 4, Analytical W
Q
Atm Asbestos Sensitivity Density Sensitivity Density Type
SciLab Client Sampled Dilution Stiuctines on Grid ; on Grid on Surface! on Surface of
Sample # Sample # (sq. cm ) Factor Detected (Str/sqmm) (Str/sq nun) (Str/sq-cm ) (Str/ sq. cm ) Asbestos
01 JD012102MV21SAH15 100.0 0.020 1 10 10.0 1,070 OJ
1,070 chrysotile Q
21st Root; Supply Air Handler fil5-Mixing Chamber Base of Cooling Cor s
02 JD012102M\"2]SAHll 100.0 0.005 11 10 110.0 4,280 47,080 chrysotile
21st Floor, Supply Air Handler #11-Mixing Chamber Base of Cooling Coi s
03 JD012102MV21RAHF12 100.0 O.IOQ 14’ 33.3 ’ 4,766.7 713 102,006 chrysotile
21 st Floor, Return Alt Handler-Fan #12 Floor of Air Duct R
m
04 JD012102MV21SAH10 100.0 0.020 0 10 <10 1,070 <1,070 NSD 2
21 st Boor; Supply Ait lfan Jler #I0-Mixu)g Chamber-Base of Cooling CoUs
T
05 JD0121C2MV21SAH08 100.0 0.020 3 10 30.0 1.070 3,210 chrysotile O
21 st Floor; Supply Air Handler #Og-Mixiiig Chamber-Base of Cooling Coils
D
Ofi JD012102MV21SAK07 100.0 0,020 1 10 10.0 1,070 1,070 chrysotile Cd
tn
21st Floor; Supply Ziir Handler #07-Mixing Chamber-Base of Cooling Coils
JD012102MV21SAH14 100.0 0.100 0 25 <25 535 <535 NSD
2 IsE Floor; Supply Air. Handler #14-Mixiiig Chamber-Base of Cooling Coi s
OS JD012102MV21R.AHF09 100,0 0.100 0 25 <25 535 <535 NSD
Return Air handler-Fan 09
OS» 3D0t2102MV21SAH01 100.0 0.002 6 10 60.0 8,560 51360 chrysotile
7th Floor; Supply Air Handler #01 -Mixing Chamber-Base of Cooling Coil
10 JD0121O2MV07RAH20 lOO.O 0.100 13 25 325.0 535 6,955 chrysotile
7!h Floor; Return Air Handler-Fan #20-Base of Duct
11 JD012102MVO7SAH02 100-0 0.010 17 10 170.0 2,140 36,380 cluysoliie
7th Floor; Supply HaDdler#02; Mixing Chamber-Base of Cooling Coils w
12 3DO12102MV07SAH03 100.0 0.020 34 10 340.0 1,070 36,380 chrysotile rc
7lh Floor; Supply Han<iler#03-Muung Chamber-Base of Cooling Coils m
-0
CD
13 JDO12102MV07SAH04 100.0 6,005 9 10 90.0 4,280 38,520 chrysotile
o 7 th Floor; Supply Hiuidler#04-Mixing Chamber-Base of Cooling Coils U
-I
14 IDO 12102MV07RAHF21 IQO.O O.lOO 1 25 25.0 535 535 chrysotile 16
___k
7th Floor; Remm Air Handler-Fan #21-Base of Duct “D
* structure density represented by the dc:tectioii of 1 structure
o ** not analyzed
o NSD; No Asbestos Structures Detected