Asbestos air sample results, 40 Rector Street, Oct 2001

Machine-extracted title · confidence 28%

Summary of asbestos air sample results for the Rector Street site.

NYC-WTC_000386208
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OCT 24 2001 12:09 FR TRNNENBAUM-HELPERN 12128385606 TO 3802666 P.02/02 ^0Z24/M8X-lt>:45 FAJ 21S 3&J-Tnn.» 104 East asth Streat 10th R- Naw York. Naw York 10010 www.aic-enviro.com 212.3S3.B20O Fsx 212353.8306

VIA FACSIMILE: 212-371-1084

October 24.2001

40 RECTOR HOLDINGS. LLC c/o TANNENBAUM HELPERN SYRACUSE & HIRSCHTRITT LLP 900 Third Avenue New York, New York 10022-4775 Attn: Mr. Scott Furman

40 RECTOR STREET, New York

Dear Mr. Furman; ATC Associates Inc. (ATC) is pleased to submit this summary report presenting the asbestos air sample results for the first through nineteenth floors of 40 Rector Street. Between September 22 and 23. 2001, ATC collected five ambient air samples par floor, totaling 90 samples to ascertain the presence or absence of airborne asbestos, within the subject fedliCy. All samples collected were analyzed in accordance with the AHERA Transmission Electron Microscopy (TEM) method as sec forth at 40 CFR Part 763, Subpart E. Appendix A. Acceptable ambient air samples results are those sample sets meeting the AHERA re-occupancy requirement following an asbestos abatement action of an average of less than 70 asbestos structures per square millimeter (<70 s/mm’). Summary of Ambient Air Sample Results for 40 Rector Street: Floor ______ Analytical Result Floor _____ Analytical Result 1 No structures detected 10 No structures detected 2 No structures detected 11 No structures detected 3 No structures detected 12 No structures detected 4 No structures detected 14 No sttuctures detected 5 Nq structures detected 15 Ne structures detected 6 No structures detected 16 No structures detected 7 No structures detected 17 No structures detected 8 Ne structures detected 18 No structures detected 9 No staictunes detected 19 No structures detected

Based upon the analytical results within the AHERA clearance requirement, it is ATC's opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy, if you have any questions or require additional axplaination of the information presented please do not hesitate to call me at 212-353-8280 Sincerely,

Fred Burkhardt Senior Project Manager ATC Associates Inc.

** TOTAL PAGE.02 **

CITY_21MC1OO_OO2836627

NYC-WTC_000386208

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386208Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000291213

AS asbestos air sample results for first-to-nineteenth floors; summary report.

Similar indexed content

Compare copies and versions →