NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Ambient group environmental survey summary, Oct 2001

Machine-extracted title · confidence 28%

Preliminary summary of indoor environmental quality survey at location.

NYC-WTC_000386189
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OCT-10-01 WED 04:36 PN FAX NO. P. 01 OCMO-01 WED 01108 PN AMBIENT GROUP INC FAX NO. 212 768 1540 P. 02

ambient groupie. ■x'AIU'V.! I|I■AI^]IA^IIU«

Indoor envfronmoiiljl quiltly Su/veyi Wer Ireaimcnl csniuWiij Post-It’ Fax Note 7671 A«b»5toj Cl lead field Rrvl««» Rcgulaloiv compliance pfojrom: f^orjitjcr Co./DL;pt Co. Afr, volcr a loil jnaly'.icjl lAborolariet Phone It Phone II Fax# ~~ October 10, 2001

Mr. Roger Kalin S. L. Green 420 Lexington Avenue New York. New York 10017

Re: 2 Washington Street Ambient Project #211502

Dear Mr. Kahn:

'Ibe following is a preliminary summary of the indoor environmental quality survey that is currcnllyl being performed by Ambient Group, Inc. at the above referenced location.

The survey includes air sample collection for transmission electron microscopy (TEM) for asbestos structures.

PlcaiC note that the method employed (TEM) (0 analyze the airborne aibestos slriicfures is the same tis the one described in the Newsweek and Dally News article dated October 9, 200J. This ntethod utilizes electrons to magnify the mage. As a result of electron bombardment, a positive tdeniificaiion of crystal structure can be made at a magnification of 20.000X. Therefore, microscopic bundles of pulverized asbestos can be detected, ideritified and considered in the risk assessment.

Tlircc (3) air samples were collected on floors 8, 11 and 20 and analyzed by transmission electron microscopy (TEM) for a.sbcstos structures. The results of the analysis indicated that airborne asbestos levels inside the building at the time of testing were less than the analytical sensitivity of the in.strumcnt, in addition to being well below the EPA standard of 70 statelurcs/mm’ and other recommended indvistry guidelines and/or regulations.

PIcjsc refer to the attached laboratory data sheet for further details. Wo will be retumin^o the building shortly to complete the survey. 5 o <=> o C~) Should you have any qaesLion.s regarding this information, please feel free to call mo. > cz> Sincerely, o Signed for Ambient Inc. by: TO o w a: William Esposito, Clll JC- .1

President

C.\200l\tnvcHl(;.iiIoiuMAiUtnMltS022 Wishiojlon Slrcci\2ll502piojccisurn 10,10,01.doc

Cl Id COVF. NY MVli, R nu<.v.c. 11 ORaNUI.. CA i'? 5.7-5, 711

CITY_21MC100_0 02836570

NYC-WTC_000386189

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386189Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →