KAK CONSb HANTS 35-40 36th Street Long Island City NewYork,11106 Tel:(718 729-W Fax: (718 729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 14-22 Reade Street, Manhattan PROJECT#: Client Sample ID# •40A 40B 40C 41A 41B

Lab Sample ID- 910905B-250 010905B-251 010905B-252 010905B-253 010905B-254 Sample Location Roof'D" Roof'D" Roof'D" Roof"D" Roof'D"

Homogeneip.' Yes Yes Yes Yes Yes Sample Description Roof Membrane Roof .Membrane Roof Membrane Roof Membrane Roof Membrane 1st Layer 2nd La\er ord Layer 1 st Layer 2nd Layer

Color Blk Blue Blk BIk Blue Texture Non Fibrous Non Fibrous Non Fibrous Non Fibrous Non Fibrous

Sample Treatment Acid Digestion Acid Digestion Acid Digestion Acid Digestion Acid Digestion & Ashing & Ashing & Ashing & Ashing & Ashing Asbestos Present. (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent)- 0% 0% 0% 0% 0%

Non Fibr Mat (Percent)- 100% 100% 100% 100% 100% Date Received. 9/5/01 Date of Analysis- 9/6/01 Date of Report. 9/7/01

Analyst: \\\ . U(6lTvdcJ<L> Lab Manage: ’m. Ulanecki David Chen * Analvsis of samples is performed bv Polarized Light Microscopv (PLM) - Point Counting Method (EPA 600/M4-82-020) ♦ Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopv is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP 4 11273 NIST-yyiAP # 102047 AIHA 4: 100269

19

NYC-WTC_000386162

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000386162Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →