Indoor air quality guidelines, Table 1

Machine-extracted title · confidence 46%

Table of target guidelines for IAQ parameters; DOAS/KAM consultant reference.

NYC-WTC_000385959–000385960
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan Date, 2002 Indoor Air Quality Assessment Page 2 P.S. XXX (Borough) ATC Project No, 15-19125-XXXX

ATC measured concentrations of with a Handheld Aerosol Monitor Model 1010, manufactured by ppnf\ Inc.

ATC measured concentrations of using a RAE Systems, Inc. MiniRAE® photoionization detector (PID),

The Biosystems PhD Ultra* portable gas detector measured carbon monoxide (CO), oxygen (Oj, and lower explosive limit of combustible gas concentrations.

ATC conducted spot checks of a smoke tube.

Ths assessments were performed consistent with generally accepted indoor air quality assessment practices. As with all such assessments, there were inherent limitations created by constraints of time, operational and work practice vanabiUiy, variations in air contaminant concentrations, and sampling and analytical accuracy. The results of ths sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the Board of Education as a guide to assess the need for further improvements in current indoor air quality control activities.

EVALUATION CRITERIA

Currently, there arc no regulatory standards for indoor air quahty in nor. industriai buildings, such as o£5ces and schools For the real-time data collected, ATC uses the commonly accepted guidelines cited in the followiiig publications;

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-2001), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), rhernial Environmental Conditions for Human Occupancy fASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quedity Investigations (1993), American Industrial Hygiene Association (AIHA).

zoo® OlV 90C8 CSC ZTZ IV^I ^S:fT ZOOZ/ZT/iO

CITY_21MC100_002836231

NYC-WTC_000385960

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000385960Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000311687

Indoor air quality assessment conducted on October 9, 2001 at Stuyvesant High School.

Similar indexed content

Compare copies and versions →