Mr. Bernard P. Orlan December T 9,2061 Real-Time Air Monitoring ®'Eage/2/; P.S. 89 (Manhattan) ■ ATC Project No. 15-19125-0297 :

ATC measured concentrations of TVOCs using a RAE Systems, Inc. MiniRAE® photoionization detector (PID). -'Nitrogen oxides and SQp were measured using a RAE Systems, Inc. VRAE® multi-gas detector. H2S was measured using a BioSystems PliD Ultra® gas detector.

The assessments were performed consistent with generally accepted indoor air quality assessment practices. As with all such assessments, there were inherent limitations created by constraints pf time, operational and work practice variability, variations in indoor air quality parameters, and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the Board of Education as a guide to assess the need for further improvements in current indoor air quality control activities.

EVALUATJON CRITERIA

Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools, For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:

Ventilationfor Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 5 5-J992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993'), American Industrial Hygiene Association (AIHA).

Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times. / 2 . 2 ■/.<■ Cfv • A ■- ;/./ . 2

TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED* .....

Carbon Dioxide ICO-j <700 parts per million (ppm) ASHRAE62 above background level Carbon Monoxide (CO) 9 ppm ASHRAE 62 (adopted from USEPA NPAAQS) / / / Respirable Particulates 65 micrograms per cubic meter of USEPANPAAQS (PMz5) air (pg/m’) 24 hour average Temperature Summer: 73-79°F at 50% RH ASHRAE 55 Winter: &8-75T at 50% RH Relative Humidity 30-60% ASHRAE55 Total Volatile Organic 1 ppm ' AIHA Compounds (TVOC) Hydrogen Sulfide (HjS) 0.01 ppm (one hour) NYSDEC Sulfur Dioxide (SO2) 0.14 ppm (24-hour average) USEPA NPAAQS Nitrogen Dioxide (NOj) 0.053 ppm (annual average) USEPA NPAAQS

USEPA = United States Environmental Protection Agency * Guidelines for NO are NPAAQS = National Primary Ambient-Air Quality Standard not available.

CITY_21MC100_003270018

NYC-WTC_000325956

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000325956Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →