NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
16 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Protocol for daily air testing inside/outside H.S. for Leadership after 9/11 events.
NYC-WTC_000385882–000385889OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
AMBIENT AIR AND DUST SAMPUNG PROTOCOL for H.S. for Leadership and Public Services (M894) Page 2 of 8
• Thirteen floor Hallway - one sample immediately after the last class
Outside the school building
The total of 4 ambient air samples shall be collected from outside the school building each day as follows:
• Outside by main entrance - 2 samples (one sample from 8am-12pm & one from 12pm- 4pm) • Roof - 2 samples (one sample from 8am-12pm & one from 12pm-4pm)
The duration of all ambient air sample shall be approximately 4 hours. The total air volume sampled at each location shall be approximately 1800 liters.
All ambient air samples collected shall be analyzed via Transmission Electron Microscopy (TEM) in accordance with the methodology of the AHERA Final Rule.
Results from samples collected each day shall be reported verbally, no later than 8am the next day, to BOE, UFT, School Principal and the PA consultant A written report shall be delivered or faxed by the end of the day. Unsatisfactory results (>70 s/mm^) shall be reported immediately. w In the event that any one sample result exceed 70 s/mm^ BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).
INDOOR AIR QUALITY
To address lAQ concerns, each day from Monday through Friday, during school hours, the following shall be performed:
• A visual inspection to assess conditions present in the school at the time of the site visit.
• Collect approximately 140 real-time environmental measurements of temperature (T)
• Collect approximately 140 real-time environmental measurements of relative humidity (RH)
• Collect approximately 140 real-time environmental measurements of carbon dioxide (CO2)
• Collect approximately 140 real-time environmental measurements of carbon monoxide (CO)
• Collect approximately 140 real-time environmental measurements of total volatile organic compounds (TVOCs)
CITY_21MC100_0 09223825
NYC-WTC_000385883
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
16 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385905
Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.
16 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385830
protocol for ambient air and dust sampling inside PS 89 Manhattan following WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385797
Ambient air/dust sampling protocol for IS 89 after WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324151
Ambient air protocol for H.S. for Leadership and [name] following WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324195
Ambient air protocol and asbestos IAQ plan for H.S. of Economics & Finance.
16 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324135
Draft IAQ protocol for asbestos monitoring at BOE schools post-WTC.
15 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
16 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200222
Draft protocol establishing daily ambient air and dust monitoring procedures for asbestos contamination at the school.
16 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324159
Ambient air/dust protocol for PS 234 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324167
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ plan.
15 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200230
Draft protocol document establishing daily ambient air and dust sampling procedures for asbestos monitoring at P.S./I.S. 89 Manhattan.
15 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000324195
Ambient air protocol and asbestos IAQ plan for H.S. of Economics & Finance.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324151
Ambient air protocol for H.S. for Leadership and [name] following WTC cleanup.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324211
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385830
protocol for ambient air and dust sampling inside PS 89 Manhattan following WTC cleanup.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000324151
Ambient air protocol for H.S. for Leadership and [name] following WTC cleanup.
Similar indexed content
NYC-WTC_000324195
Ambient air protocol and asbestos IAQ plan for H.S. of Economics & Finance.
Similar indexed content
NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
Similar indexed content
NYC-WTC_000324135
Draft IAQ protocol for asbestos monitoring at BOE schools post-WTC.
Similar indexed content
NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
Similar indexed content