Ambient air protocol, H.S. for Leadership, 2002

Machine-extracted title · confidence 64%

Ambient air protocol for H.S. for Leadership and [name] following WTC cleanup.

NYC-WTC_000324151–000324158
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

1

AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.S. for Leadership and Public Sendees (MS94) Page 2 of 8

• I hirteen floor Hallway - one sample immediately after the last class

Outside the school building

The total of 4 ambient air samples shall be collected from outside the school building each day as follows:

• Outside by main entrance - 2 samples (one sample from 8am-12pm & one from 12pm- 4pm) • Roof - 2 samples (one sample from 8am-12pm & one from 12pm-4pm)

The duration of all ambient air sample shall be approximately 4 hours. The total air volume sampled at each location shall be approximately 1800 liters.

All ambient air samples collected shall be analyzed via Transmission Electron Microscopy (TEM) in accordance with the methodology of the AHERA Final Rule.

Results from samples collected each day shall be reported verbally, no later than Sam the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day. Unsatisfactory results (>70 s/mm^) shall be reported immediately.

in the event that any one sample result exceed 70 s/mm" BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

INDOOR AIR QUALITY

To address lAQ concerns, each day from Monday through Friday, during school hours, the following shalLbe performed: !' • A visual inspection to assess conditions present in the school at the time of the site visit.

• Collect approximately 140 real-time environmental measurements of temperature (T)

• Collect approximately 140 real-time environmental measurements of relative humidity ■ (RH)

• Collect approximately 140 real-time environmental measurements of carbon dioxide (CO2)

• Collect approximately 140 real-time environmental measurements of carbon monoxide (CO)

• Collect approximately 140 real-time environmental measurements of total volatile organic compounds (TVOCs)

CITY_21MC1OO_OO3267194

NYC-WTC_000324152

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324152Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →