5 AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.S. of Economics and Rnance Page 2 of 8
• Outside by main enfrance - 2 samples (one sample from 8am-12pm & one from 12pm- 4pm) • Stair case B (open stair case) T” Floor landing - 2 samples (one sample from 8am-12pm & one from 12pm-4pm) • Roof - 2 samples (one sample from 8am-12pm & one from 12pm-4pm)
The duration of all ambient air sample shall be approximately 4 hours. The total air volume sampled at each location shall be approximately 1800 liters.
All ambient air samples collected shall be analyzed via Transmission Electron Microscopy (TEM) in accordance with the methodology of the AHERA Final Rule.
Results from samples collected each day shall be reported verbally, no later than 8am the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day. Unsatisfactory results (>70 s/mm^ shall be reported immediately.
In the event that any one sample result exceed 70 s/mm^ BOE will immediately notify the LIFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).
INDOOR AIR QUALITY
To address lAQ concerns, each day from Monday through Friday, during school hours, the following shall be performed:
• A visual inspection to assess conditions present in the school at the time of the site visit.
Collect approximately 100 real-time environmental measurements of temperature (T>
• Collect approximately 100 real-time environmental measurements of relative humidity (RH)
• Collect approximately 100 real-time environmental measurements of carbon dioxide (CO2)
• Collect approximately 100 real-time environmental measurements of carbon monoxide (CO)
• Collect approximately 100 real-time environmental measurements of total volatile organic compounds (TVOCs)
• Collect approximately 100 real-time environmental measurements of respirable particulates (PM2.5).
EVALUATION CRITERIA:
CITY_21MC100_003267221
NYC-WTC_000200223
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
15 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
7 shared non-person entities · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153247
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
7 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
9 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
9 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
9 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139656
Forwarded spreadsheet compiling residential asbestos sampling results collected in November-December 2001, including Building 11 reoccupancy assessment.
9 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164960
Draft compilation of asbestos air samples collected from residential areas November-December 2001 by NYC DOH and ATSDR.
9 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152825
Draft protocol establishing procedures for evaluating airborne and settled dust in residential and commercial areas near the World Trade Center.
7 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
6 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
Similar indexed content
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similar indexed content
NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
Similar indexed content