NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 8 pages

NYC-WTC_000234651

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000234651–000234658
Page image
Scanned page image, NYC-WTC_000234652
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AMBIENT AIR AND DUST SAMPLING PROTOCOL for PS/IS89M. Page 2 of 8

• Inside Playground south side - 2 samples (one sample from 8am-12pm & one from 12pm- 4pm) • Fifth floor roof - 2 samples (one sample from 8am-12pm & one from 12pm-4pm) The duration of all ambient air sample shall be approximately 4 hours. The total air volume sampled at each location shall be approximately 1800 liters.

All ambient air samples collected shall be analyzed via Transmission Electron Microscopy (TEM) in accordance with the methodology of the AHERA Final Rule.

Results from samples collected each day shall be reported verbally, no later than 8am the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day. Unsatisfactory results (>70 s/mm^) shall be reported immediately.

In the event that any one sample result exceed 70 s/mm" BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

INDOOR AIR QUALITY

To address lAQ concerns, each day from Monday through Friday, the following shall be performed:

• A visual inspection to assess conditions present in the school at the time of the site visit.

• Collect approximately 80 real-time environmental measurements of temperature (T)

Collect approximately 80 real-time environmental measurements of relative humidity (RH)

• Collect approximately 80 real-time environmental measurements of carbon dioxide (CO2)

• Collect approximately 80 real-time environmental measurements of carbon monoxide (CO) • Collect approximately 80 real-time environmental measurements of total volatile organic compounds (TVOCs)

• Collect approximately 80 real-time environmental measurements of respirable particulates (PM2.5).

Evaluation Criteria:

Since, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools at this time, for the real-time data collected, the commonly accepted guidelines cited in the following publications and table below shall be utilized:

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of

CITY_21MC100_009363864

NYC-WTC_000234652

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000234652Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000153247 · Box DEP Box 26

Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.

Similar indexed content

Compare copies and versions →