AMBIENT AIR AND DUST SAMPUNG PROTOCOL for PS/1S89M. Page2of9
• Inside Playground south side - 2 samples (one sample from 8am-12pm & one from 12pm-4pm) • Fifth floor roof - 2 samples (one sample from 8am-12pm & one from 12pm-4pm) The duration of all ambient air sample shall be approximately 4 hours. The total air. volume sampled at each location shall be approximately 1800 liters.
All ambient air samples collected shall be analyzed via Transmission Electron Microscopy (TEM) in accordance with the methodology of the AHERA Final Rule.
Results from samples collected each day shall be reported verbally, no later than 8am the next day, to BOE, LIFT, School Prindpal and the PA consultant A written report shall be delivered or faxed by the end of the day. Unsatisfactory results (>70 s/mm^) shall be reported immediately.
In the event that any one sample result exceed 70 s/mm^ ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the UFT and the PA consultant. BOE shall notify the school prindpal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.
INDOOR AIR QUALITY
To address lAQ concerns, each day from Monday through Friday, the following shall be performed:
• A visual inspection to assess conditions present in the school at the time of the site visit
• Collect approximately 80 real-time environmental measurements of temperature (T)
Collect approximately 80 real-time environmental measurements of relative humidify (RH)
• Collect approximately 80 real-time environmental measurements of carbon dioxide (CO2)
• Collect approximately 80 real-time environmental measurements of carbon monoxide (CO) • Collect approximately 80 real-time environmental measurements of total volatile organic compounds (TVOCs)
• Collect approximately 80 real-time environmental measurements of respirable particulates (PM2.5).
EVALUATION CRITERIA:
Since, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools at this time, for the real-time data collected, the commonly accepted guidelines cited in the following publications and table below shall be utilized:
CITY_21MC100_0 09214702
NYC-WTC_000385831
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000385797
Ambient air/dust sampling protocol for IS 89 after WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385819
Lab protocol outlining ambient air and dust sampling for asbestos at IS 89 Manhattan.
16 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385808
Protocol detailing daily ambient air sampling inside the IS 89 building.
16 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324167
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ plan.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200230
Draft protocol document establishing daily ambient air and dust sampling procedures for asbestos monitoring at P.S./I.S. 89 Manhattan.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324211
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324176
Ambient air and dust sampling protocol for PS 89 Manhattan, asbestos monitoring.
16 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324159
Ambient air/dust protocol for PS 234 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324143
Ambient air and dust sampling protocol for PS 150 in Manhattan.
16 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234651
Draft protocol document outlining daily asbestos testing procedures for ambient air at P.S./I.S. 89 Manhattan following the WTC tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324203
Ambient air and dust sampling protocol for PS 234; asbestos-monitoring.
16 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000324211
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385797
Ambient air/dust sampling protocol for IS 89 after WTC cleanup.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200230
Draft protocol document establishing daily ambient air and dust sampling procedures for asbestos monitoring at P.S./I.S. 89 Manhattan.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385819
Lab protocol outlining ambient air and dust sampling for asbestos at IS 89 Manhattan.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385808
Protocol detailing daily ambient air sampling inside the IS 89 building.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324176
Ambient air and dust sampling protocol for PS 89 Manhattan, asbestos monitoring.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000324167
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ plan.
Similar indexed content
NYC-WTC_000200230
Draft protocol document establishing daily ambient air and dust sampling procedures for asbestos monitoring at P.S./I.S. 89 Manhattan.
Similar indexed content
NYC-WTC_000385797
Ambient air/dust sampling protocol for IS 89 after WTC cleanup.
Similar indexed content
NYC-WTC_000324211
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ.
Similar indexed content
NYC-WTC_000385819
Lab protocol outlining ambient air and dust sampling for asbestos at IS 89 Manhattan.
Similar indexed content