DRAFT REV. 2/25/02
AMBIENT AIR AND DUST SAMPLING PROTOCOL
FOR
PSI 50 MANHATTAN
The New York City Board of Education (BOE) in an effort to address concerns regarding Indoor Air Quality (lAQ) and potential asbestos contamination of the ambient air at P.S. 150 Manhattan following the World Trade Center (WTC) tragedy and associated clean up work had established the following lAQ and ambient air monitoring/assessrnent protocol;
ASBESTOS
To address the concerns regarding the potential of asbestos contamination of the ambient air, daily air testing and analysis shall be performed, including Saturdays and Sundays, inside and outside the school building as follows;
Irside the schcof building
The total of 5 ambient air samples shall be collected from inside the school building each day as follows;
• Lobby - 2 samples (one sample from 8am-12pm & one from 12pm-^tpm)
• Multipurpose Room near kitchen - one sample immediately after the last class
Two Classrooms - 2 samples (one sample in each randomly selected classroom immediately after the last class).
Outside the school building
The total of 2 ambient air samples shall be collected from outside the school building each day as follovi/s:
• Plaza - 2 samples (one sample from 8am-12pm & one from 12pm-4-pm)
The duration of all ambient air samples shall be approximately 4 hours. The total air volume sampled at each location shall be approximately 1800 liters.
All ambient air samples collected shall be analyzed via Transmission Electron Microscopy (TEM) in accordance with the methodology of the AHERA Final Rule.
Results from samples collected each day shall be reported verbally, no later than Sam the next day, to E3OE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day. Unsatisfactory results (>70 s/mm^) shall be reported immediately.
CITY_21MC100_0 09214723
NYC-WTC_000385841
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000385851
Draft ambient air sampling protocol for PS 150 Manhattan with lAQ considerations.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385777
Protocol for ambient air and dust sampling around PS 234 post-WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385787
Ambient air sampling protocol for PS 234 with daily inside/outside tests.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385819
Lab protocol outlining ambient air and dust sampling for asbestos at IS 89 Manhattan.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385808
Protocol detailing daily ambient air sampling inside the IS 89 building.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324143
Ambient air and dust sampling protocol for PS 150 in Manhattan.
16 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324159
Ambient air/dust protocol for PS 234 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324203
Ambient air and dust sampling protocol for PS 234; asbestos-monitoring.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324176
Ambient air and dust sampling protocol for PS 89 Manhattan, asbestos monitoring.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324211
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234651
Draft protocol document outlining daily asbestos testing procedures for ambient air at P.S./I.S. 89 Manhattan following the WTC tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000324143
Ambient air and dust sampling protocol for PS 150 in Manhattan.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385851
Draft ambient air sampling protocol for PS 150 Manhattan with lAQ considerations.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385797
Ambient air/dust sampling protocol for IS 89 after WTC cleanup.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385819
Lab protocol outlining ambient air and dust sampling for asbestos at IS 89 Manhattan.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324167
Ambient air sampling protocol for PS 89 Manhattan; asbestos IAQ plan.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000324185
Ambient air sampling plan for PS 150 Manhattan; asbestos IAQ.
Similar indexed content
NYC-WTC_000385851
Draft ambient air sampling protocol for PS 150 Manhattan with lAQ considerations.
Similar indexed content
NYC-WTC_000324143
Ambient air and dust sampling protocol for PS 150 in Manhattan.
Similar indexed content
NYC-WTC_000324159
Ambient air/dust protocol for PS 234 Manhattan; asbestos IAQ.
Similar indexed content
NYC-WTC_000385777
Protocol for ambient air and dust sampling around PS 234 post-WTC cleanup.
Similar indexed content