Mr. Bernard P. Orlan February 4, 2002 Indoor Air Quality Assessment Page 4 P. S. 89M ATCProiectNo. 15-19125-0297

Respirable Particulates (PM2,5)

Respirable particulate concentrations* indoors ranged from 12 pg/m^ to 29 pg/m^ (A.M.) and 46 pg/m3 to 59 pg/m^ (P.M.). All indoor measurements were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less m aerodynamic diameter. The average PM2.5 concentration* for the entire school building was approximately 23 pg/m3 (A.M.) and 49 pg/m^ (P.M.). All A.M. indoor measurements were also below the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children, only two (2) P.M. measurements were below this level. The outdoor respirable particulate concentration averaged 41 pg/m^ (A.M.) and 90 pg/m^ (P.M.).

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.

TVOC Concentration

TVOCs were not detected (0.0 ppm) anywhere inside or outside the building.

OBSERVATIONS

During this assessment, ATC noted the following:

• The interior of the building appeared clean and free of dust and debris; • The school was partially occupied (I.S. 89) at the time of the assessment; • No smoke odor was detected in the building.

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. Measurements of relative humidity and concentrations of CO and TVOCs were within applicable guidelines; 2. All but three (3) measurements of temperature were within the recommended range; 3. Instantaneous readings of PM2.5 concentrations were below the NPAAQS of 65 pg/m^ however twenty (20) P.M. readings were above the recommended level of 40 pg/m^ for sensitive individuals and children; 4. Six (6) measurements of CO2 were above the ASHRAE-recommended maximum concentration.

CITY_21MC100_000466516 NYC-WTC_000382543

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000382543Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

IAQ memo, PS 89M, Jan 2002

NYC-WTC_000400632

Report of indoor air quality measurements at PS 89M; January 28, 2002.

Similar indexed content

Compare copies and versions →