NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Correspondence: lAQ report for PS 234M, Feb 2002

Machine-extracted title · confidence 42%

Cover letter from ATC presenting indoor air quality measurements requested by NYC BOE for PS 234M.

NYC-WTC_000382004–000382007
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan February 6, 2002 Indoor Air Quality Assessment Page 4 P.S274M ATC Project No. 15-19125-0279

as asthmatic people and children. The outdoor respirable particulate concentration ranged from 9 to 14 pg/m3 with an average of 11 ^g/m^.

* The measurements made during this assessment were instantaneous readings, the NP.A.4QS is a 24-hour average.

rVOC Concenlradon

TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm. OBSERVATIONS

During this assessment, ATC noted the following; • The building was occupied at the time of the assessment; • No smoke odor was detected in the building;

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. Concentrations of CO and TVOCs were within applicable standards aid guidelines. 2. None of the PM2.5 measurements were above the NPAAQS of 65 pg/nP or above the USEPA recommended PM2.5 concentration of 40 pg/m^ for sensitive individuals and children. 3. One (1) temperature measurement was below and one (1) was above the range of 68 to 75*3 F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992. 4. Nine (9) CO, measurement was above the range recommended by ASHRAE 62-1999. All others were below the maximum concentration. 5. All but one of the indoor measurements of relative humidity were below the ASHRAE recommended range of 30 to 60 percent for occupant comfort.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280. e.xtension 261 or 212.

Sincerely, Reviewed by; A TC ASSOCIA TES INC.

Andreas G. Andreou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division

Attachment

CITY_21MC100_002878457

NYC-WTC_000382007

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000382007Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

IAQ report, PS 234M, Feb 2002

NYC-WTC_000382038

ATC indoor air quality report for PS 234M, February 2002, BOE request noted.

Similar indexed content

Compare copies and versions →