NYC-WTC_000314706
Indoor air quality measurements at PS 234M, Feb 11, 2002, per BOE request.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Memo: IAQ measurements at P.S. 234M, school site, requested by NYC BOE.
NYC-WTC_000272216–000272219OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan February 13, 2002 Indoor Air Quality Assessment Page 4 P. S. 234M ATC Project No. 15-19125-0279
as asthmatic people and children. The outdoor respirable particulate concentration ranged from 10 to 23 pg/m^ with an average of 15 Ug mG
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TVOC Concentration
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm. OBSERVATIONS
During this assessment, ATC noted the following: • The building was occupied at the time of the assessment; • No smoke odor was detected in the building.
FINDINGS
Based on the real-time measurements, the following findings are presented:
1. Concentrations of CO and TVOCs were within applicable standards and guidelines. 2. None of the PM2.5 measurements were above the NPAAQS of 65 pg/m^ or above the USEPA recommended PM2.5 concentration of 40 pg/m^ for sensitive individuals and children. 3. Ten (10). CO2 measurements were above the range recommended by ASHRAE 62-1999. All others were below the maximum concentration. 4. Only one (1) indoor measurement of relative humidit>' was within the ASHRAE recommended range of 30 to 60 percent for occupant comfort. All other measurements were below the recommended range. 5. Eight (8) of the temperature measurement were below the range of 68 to 75°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions).
It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 261 or 212.
Sincerely, A TC ASSOCL4 TES INC. Reviewed by:
Yiannis Efstathiou James R. Cohn, CIH, CSP Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_003101691
NYC-WTC_000272219
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000314706
Indoor air quality measurements at PS 234M, Feb 11, 2002, per BOE request.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314875
IAQ measurements collected March 11, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199173
Letter from ATC Associates reporting indoor air quality measurements collected at P.S. 234M on February 12, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314690
IAQ measurements report for PS 234M requested by BOE.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314646
ATC indoor air quality measurements report for PS 234M (Feb 2002).
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182883
Report of indoor air quality measurements collected at PS 234M on February 13, 2002, to assess acceptable air quality conditions.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382100
ATC report on indoor air quality tests at the referenced school for BOE evaluation, Feb 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314888
IAQ measurements collected March 7, 2002 at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272279
IAQ measurements conducted at P.S. 234M for BOE program.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383700
Memo re: indoor air quality measurements at PS 89M, Feb 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315412
ATC IAQ measurements report for P.S. 234M to Board of Education.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294387
Report of IAQ measurements at PS 234M for BOE program, dated March 7, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000314690
IAQ measurements report for PS 234M requested by BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314646
ATC indoor air quality measurements report for PS 234M (Feb 2002).
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314680
IAQ measurements report for PS 234M by ATC.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294401
ATC IAQ report for PS 234M, measurements taken March 11, 2002, for BOE.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272200
ATC indoor air quality report for P.S. 234M, Feb 8, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314716
IAQ measurements at PS 234M collected Feb 8, 2002 for BOE program.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000314706
Indoor air quality measurements at PS 234M, Feb 11, 2002, per BOE request.
Similar indexed content
NYC-WTC_000314875
IAQ measurements collected March 11, 2002 at PS 234M for BOE.
Similar indexed content
NYC-WTC_000199173
Letter from ATC Associates reporting indoor air quality measurements collected at P.S. 234M on February 12, 2002.
Similar indexed content
NYC-WTC_000314690
IAQ measurements report for PS 234M requested by BOE.
Similar indexed content
NYC-WTC_000314646
ATC indoor air quality measurements report for PS 234M (Feb 2002).
Similar indexed content