NYC-WTC_000272232
IAQ measurements conducted at the referenced school for BOE program.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗IAQ measurements report for PS 234M by ATC.
NYC-WTC_000314680–000314683OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan February 15, 2002 Indoor Air Quality Assessment Page 4 P. S. 234M ATC Project No. 15-19125-0279
as asthmatic people and children. The outdoor respirable particulate concentration ranged from 34 to 46 pg/m^ with an average of 43 pg/m^.
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TVOC Concentration
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm. OBSERVATIONS
During this assessment, ATC noted the following; • The building was occupied at the time of the assessment; • No smoke odor was detected in the building.
FINDERS
Based on the real-time measurements, the following findings are presented;
1. Concentrations of CO and TVOCs were within applicable standards and guidelines. 2. None of the PM2,5 measurements were above the NPAAQS of 65 pg/m^ or above the USEPA recommended PM2.5 concentration of 40 pg/m^ for sensitive individuals and children. 3. Eighteen (18) CO, measurements were above the range recommended by ASHRAE 62-1999. All others were below the maximum concentration. 4. Only one (1) indoor measurement of relative humidity was within the ASHRAE recommended range of 30 to 60 percent for occupant comfort. All other measurements were below the recommended range. 5. one (1) of the temperature measurement was below and thirteen (13) temperature measurements were above the range of 68 to 75°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions).
It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 261 or 212.
Sincerely, J TC ASSOCIA TES INC. Reviewed by:
Yiannis Efstathiou James R. Cohn, CIH, CSP Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_003031850
NYC-WTC_000314683
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000272232
IAQ measurements conducted at the referenced school for BOE program.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314716
IAQ measurements at PS 234M collected Feb 8, 2002 for BOE program.
11 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382038
ATC indoor air quality report for PS 234M, February 2002, BOE request noted.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272178
Indoor air quality measurements report for PS 234M, Feb 5, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314726
Report of IAQ measurements at PS 234M for BOE; Feb 7, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272200
ATC indoor air quality report for P.S. 234M, Feb 8, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314742
IAQ measurements at PS 234M; Feb 5, 2002, per BOE request.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314646
ATC indoor air quality measurements report for PS 234M (Feb 2002).
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382004
Cover letter from ATC presenting indoor air quality measurements requested by NYC BOE for PS 234M.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382100
ATC report on indoor air quality tests at the referenced school for BOE evaluation, Feb 2002.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314706
Indoor air quality measurements at PS 234M, Feb 11, 2002, per BOE request.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272216
Memo: IAQ measurements at P.S. 234M, school site, requested by NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000314646
ATC indoor air quality measurements report for PS 234M (Feb 2002).
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314690
IAQ measurements report for PS 234M requested by BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382100
ATC report on indoor air quality tests at the referenced school for BOE evaluation, Feb 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294401
ATC IAQ report for PS 234M, measurements taken March 11, 2002, for BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272216
Memo: IAQ measurements at P.S. 234M, school site, requested by NYC BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272200
ATC indoor air quality report for P.S. 234M, Feb 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000272232
IAQ measurements conducted at the referenced school for BOE program.
Similar indexed content
NYC-WTC_000314716
IAQ measurements at PS 234M collected Feb 8, 2002 for BOE program.
Similar indexed content
NYC-WTC_000382038
ATC indoor air quality report for PS 234M, February 2002, BOE request noted.
Similar indexed content
NYC-WTC_000272178
Indoor air quality measurements report for PS 234M, Feb 5, 2002.
Similar indexed content
NYC-WTC_000314726
Report of IAQ measurements at PS 234M for BOE; Feb 7, 2002.
Similar indexed content