NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Letter: Air sampling, PS 150M, Leadership HS

Machine-extracted title · confidence 45%

ATC letter reporting air sampling results for Leadership School.

NYC-WTC_000376674–000376676
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

January 30, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Dioxins High School for Leadership and Public Service (894M) ATC Project No. 15-19125-0290

Dear Mr. Orlan;

ATC Associates, Inc. (ATC) is pleased to provide this letter report of the results of air sampling for polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) conducted on December 29, 2001, at the referenced school. The New York City Board of Education (BOE) requested this sampling requested these samples to evaluate possible contamination in the school building.

SCOPE OF WORK

ATC collected nine (9) samples for dioxins at specified locations. Samples were collected for twenty-four (24) hours using polyurethane foam (PUF) cartridges and General Metal Works samplers. Total sample volumes were 418 to 625 cubic meters of air (m^). Pumps were calibrated using vendor-provided software and a laptop computer. Seven (7) samples were collected inside the building and two (2) were collected outdoors. The PUFs were provided and analyzed by Pace Analytical Services, Inc., (Pace) of Minneapolis, MN, a laboratory experienced in dioxin analysis. The analysis was performed by Method TO-9 with modifications fi-om EPA Method 23 using combined capillary column gas chromatography/high resolution mass spectrometry. Copies of the draft analysis reports are attached..

The sampling locations were specified by the parent’s association consultant. They were as follows: Library 13“’ Floor, Lobby Main Entrance, 3*“ Floor Hallway by North Stairs, 11“' Floor Room 1106 South, Room 503 5* Floor North, Room 715 7* Floor South, Room 903 9" Floor North, Roof by the air intake and outdoor by the Main Entrance.

SUBSTANCE DESCRIPTION

“Dioxins” or “dioxin” is a name used for a group of chlorinated multi-ringed organic compounds that includes polychlorinated dibenzo dioxins (PCDDs) and polychlorinated dibenzo furans (PCDFs). They are related to polychlorinated biphenyls (PCBs). PCDDs and PCDFs are not produced commercially except for research purposes. They occur as trace level by-products of combustion and industrial chemical processes.

CITY_21MC100_002854195

NYC-WTC_000376674

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000376674Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →