104 East 25th Street New York. New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

January 2, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Dioxins P.S. 234M ATC Project No. 15-19125-0279

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of the results of air sampling for polychlorinated dibenzb-p-dioxins (PCDDs) and dibenzofurans (PCDFs) conducted on December 6 and 9, 2001, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of Environ Corp., a consultant retained by the parents association.

SCOPE OF WORK

On each day, ATC collected eight (8) samples for dioxins at specified locations. Samples were collected for twenty-four (24) hours using polyurethane foam (PUF) cartridges and General Metal Works samplers. Total sample volumes were 402 to 638 cubic meters of air (nf). Pumps were calibrated using vendor-provided software and a laptop computer. Four (4) samples were collected inside the building and four (4) were collected outdoors. One blank sample was also submitted on December 6"’. Tire PUFs were provided and analyzed by Pace Analytical Services, Inc., (Pace) of Minneapolis, MN, a laboratory experienced in dioxin analysis.,. The analysis was perfonned by Method TO-9 with modifications from EPA Method 23 using combined capillary column gas chromatography/high resolution mass spectrometry A copy of the complete laboratory report is attached..

The sampling locations were specified by the parents association consultant. They were as follows: Cafeteria, Room 118, 2’“* floor hallway, Room 31'5, Outdoors by main entrance, Outdoors in front courtyard, Outdoors in back playground, Roof by the air intake.

SUBSTANCE DESCRIPTION

“Dioxins” or “dioxin” is a name used for .a group of chlorinated multi-ringed organic compounds that includes polychlorinated dibenzo dioxins (PCDDs) and polychlorinated dibenzo furans (PCDFs). They are'related to polychlorinated biphenyls (PCBs). PCDDs and PCDFs are not produced commercially except for research purposes. They occur as trace level by-products of combustion and industrial chemical processes.

CITY_21MC100_002890322

NYC-WTC_000395801

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000395801Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →