Indoor air quality report, PS234M, May 2002

Machine-extracted title · confidence 42%

ATC IAQ measurements collected May 23, 2002 for PS 234M per BOE program.

NYC-WTC_000372037–000372040
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr, Bernar.! P. Orlun Mav 24,2002 ■)

IiiiJoor Ail Quality .Assessment Page P. S. 2.34M ATC Proicct No. J y 19 f254_);2 0

fi e results of the sampl.ng represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in ihrs report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.

EVALUATION CRITERIA

Cun’cntly, llicre are no regulatory standards for indoor air quality in non-industrial buildirigs. siieh as offices and schools, for the real-time data collected, AFC uses the commonly accepted guidelines cited in the Id lowing puhliealions;

i'e ililiiliDH for Acee/vuhle /rdoor Air Oiicilily (ASURAE 62-1999), American Society of Heating. Refrigerating, and Air-Conditioning Engineers (ASHRAE); « Th' -rnidi E>iviri»i»icii!ii! CdihHHoii.s for Unman Occupancy (ASJJRA ff 55 1992); bii’i<':irial Hvyitnisiy (iiiidc to Indoor Air Quality Invc.'iliyatioic'i (1993), .American Ineustrial Hygiene .Association (AIHA).

fable 1 lists target guidelines for the parameters that A'fC’ evaluated during this investigation. Meeting one. some, or all of the listed values does not assure that acceptable indoor air (|uality w ill be achieved at all times.

TABLE 1 TARGET (JITDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED PARAMETER TARGE!LEVEL AGENCY OR ORGANIZATION (.'arbon Eioxidc <700 parts per million (ppm) ASH RAE 62 (CO2) above background level 6’arbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEP.A NPAAQS Particulaics (PM2.5) of air 24-hour average 40 |ig'fn3 24-hour average USEPA - recommendation for childrcn/sensitivc individuals Temperaiure Summer: 73-79^F at 50% RH ASHRAE 55 Winter: 68-75°f at 50% RI I Relative Humidity 3(b^R.’ ASURAE 55 Total Vo aide Organic । 'ompounds I ppm Al HA (TVOC) I tSEPA - tinned Stales Environmental Protection Agency NPAAOS " National Primary Aiiibienl-Air Quality Standard AIHA " Anerican Industrial Hvaiene Association

CITY_21MC10 0_0 02 85^02 0

NYC-WTC_000372038

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000372038Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Indoor air quality report, PS 234M, May 2002

NYC-WTC_000212701

Cover letter and report from ATC Associates detailing indoor air quality measurements collected at PS 234M on May 22, 2002, for the New York City Board of Education.

Similar indexed content

Compare copies and versions →