IAQ measurement report, High School of Economics and Finance, Apr

Machine-extracted title · confidence 41%

ATC report of IAQ measurements collected April 16, 2002 for NYC BOE program.

NYC-WTC_000259192–000259195
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan April 17, 2002 Indoor Air Quality Assessment Page 2 H.S. ('f Economics and Finance (M833) AK^ Proiect No. 15-19125-0291

The rjsults of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented m this report should be used by the BOE as a guide to assess the need for further improvements in current indoor ai;' quality control activities.

EVALUATION CRITERIA

Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such us offices and schools. For the real-time data collected, ATC uses the commonly accepted guideline.s cited in the following publications:

Ventiltition for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society o:: Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality' will he achieved at all times.

TABLE 1 TARGET GTTDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED

PARAMETER TARGET LEVEL AGENCY OR ORGANIZATION Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CC2) above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CC) USEPA NPAAQS) Resoirable 65 micrograms per cubic meter USEPA NPAAQS Particulates (PM2 5) of air (pg/'m^) 24-hour average 40 pg/m^ 24-hour average USEPA - Recommendation for children / sensitive individuals Temperature Summer: 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30 60 % ASHRAE 55 Total Volatile Organic Compounds 1 ppm AIHA (TVOC) USEIA = United States Environmental Protection Agency NPArtQS = National Primary Ambient-Air Quality Standard AlII?- = American Industrial Hygiene Association

CONFIDENTIAL, CITY_21MC1OO_OO3462268 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000259193

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000259193Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000404467

IAQ measurements at 100 Trinity Place, performed April 9, 2002.

Similar indexed content

NYC-WTC_000259208

Report of indoor air quality measurements collected April 22, 2002 for BOE.

Similar indexed content

NYC-WTC_000259196

ATC indoor air quality measurements conducted April 17, 2002 for BOE review.

Similar indexed content

NYC-WTC_000259471

ATC indoor air quality report for the BOE-ordered measurements at the referenced school.

Similar indexed content

NYC-WTC_000259244

ATC report of IAQ measurements collected April 25, 2002 for BOE.

Similar indexed content

Compare copies and versions →