NYC-WTC_000371997
ATC IAQ measurements at PS 234M, May 16–17, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC Associates indoor air quality measurements at PS 234M for BOE in May 2002.
NYC-WTC_000371911–000371914OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 2,2002 Indoor Air Quality Assessment Page 3 P. S. 234M______________________________ ATC Project No. 15-19125-0279 Real-Time Environmental Measurements
ATC collected sixty (60) sets of real-time environmental measurements consisting of fifty-one (51) from inside the school building and nine (9) outdoors. All three floors of the school were surveyed. Tliese results are described below.
Field data sheets are found in Attachment 1. Readings began at 2:00 P.M. and concluded after 4:15 P.M.
Temperature
Indoor dry bulb temperature measurements ranged from 67°F to 80.5°F. Fourteen (14) indoor measurements for temperature were below, three (3) measurements were above, and thirty-four (34) measurements were within the range of 73 to 79°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the summer season. lEe outdoor temperature measurements ranged from 59 to 61.5°F.
Relative Humidity
The relative humidity indoors ranged from 25.3 percent to 38.1 percent. Forty-two (42) indoor measurements for relative humidity were below and nine (9) measurements were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity ranged from 29.3 to 35.8 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 575 ppm to 1088 ppm. All of the measurements were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 485 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1185 ppm (background level + 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors was 0 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations ranged from 1 ppm for all readings.
Respirable Particulates (PM2 5)
Respirable particulate concentrations* indoors ranged between 5 pg/m^ to 29 pg/m^ with an average 11 pg/m^- All measurements collected indoors for respirable particulate concentrations were below the NPAAQS 65 pg/m3 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m3 for sensitive individuals and children. The outdoor respirable particulate concentration ranged from 20 pg/m^ to 70 pg/m^ with an average of 28 pg/m^.
CITY_21MC100_002851856
NYC-WTC_000371913
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000371997
ATC IAQ measurements at PS 234M, May 16–17, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315270
ATC report of indoor air quality measurements at PS 234M; BOE program, May 29, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397479
ATC reports indoor air quality measurements at PS 234M, May 2002, per BOE request.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315204
Indoor air quality measurements collected May 16, 2002 at PS 234M.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315193
Indoor air quality measurements collected May 15, 2002 at PS 234M.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315182
Indoor air quality measurements collected May 14, 2002 for PS 234M.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397489
ATC provides IAQ measurements for P.S. 234M in May 2002 per BOE request.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397465
ATC IAQ measurements at PS234M, May 14, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315149
ATC IAQ measurements at PS 234M for BOE program, May 9, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315039
Air quality measurements taken April 24, 2002 for PS 234M, per BOE program.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315171
Indoor air quality measurements collected May 13-14, 2002 at PS 234M.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371915
ATC indoor air quality measurements for PS 234M requested by NYC BOE, May 2002.
11 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000371877
ATC IAQ measurements collected at PS 234M in April 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315204
Indoor air quality measurements collected May 16, 2002 at PS 234M.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315039
Air quality measurements taken April 24, 2002 for PS 234M, per BOE program.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397345
BOE-required IAQ measurements at PS 234M; report date April 25, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371997
ATC IAQ measurements at PS 234M, May 16–17, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371895
ATC IAQ measurements collected at P.S. 234M in April 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000371997
ATC IAQ measurements at PS 234M, May 16–17, 2002.
Similar indexed content
NYC-WTC_000315270
ATC report of indoor air quality measurements at PS 234M; BOE program, May 29, 2002.
Similar indexed content
NYC-WTC_000397479
ATC reports indoor air quality measurements at PS 234M, May 2002, per BOE request.
Similar indexed content
NYC-WTC_000315204
Indoor air quality measurements collected May 16, 2002 at PS 234M.
Similar indexed content
NYC-WTC_000315193
Indoor air quality measurements collected May 15, 2002 at PS 234M.
Similar indexed content