Mr. Bernard P. Orlan April 30,2002 Indoor Air Quality Assessment Page 3 P. S. 234M______________________________ ATC Project No. 15-19125-0279 Real-Time Environmental Measurements

ATC collected sixty (60) sets of real-time enyironmental measurements consisting of fifty-one (51) from inside the school building and nine (9) outdoors. All three floors of the school were surveyed. These results are described below.

Field data sheets are found in Attachment 1. Readings began at 2:00 P.M. and concluded after 4:05 P.M.

Temperature

Indoor dry bulb temperature measurements ranged from 67.6°F to 76.6 °F. Nineteen (19) of the indoor measurements for temperature were below and thirty-two (32) measurements were within the range of 73 to 79°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the summer season. The outdoor temperature measurements ranged from 48.6 to 52 °F.

Relative Humidity

The relative humidity indoors ranged from 27.3 percent to 38.6 percent. Seventeen (17) of the indoor measurements for relative humidity were below and thirty-four (34) measurements were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity ranged from 20.2 to 21.2 percent.

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 520 ppm to 958 ppm. All of the measurements were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 468 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1168 ppm (background level •+• 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors were 0 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations were 1 ppm for alt readings.

Respirable Particulates (PM2,3)

Respirable particulate concentrations* indoors ranged between 3 ^g/m^ to 13 gg/m^ with an average 6 gg/m^- All measurements collected indoors and outdoors for respirable particulate concentrations were below the NPAAQS 65 gg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 gg/m^ for sensitive individuals and children. The outdoor respirable particulate concentration ranged from 3 gg/m^ to 11 gg/m^ with an average of 6 gg/m^.

CITY_21MC100_002851845

NYC-WTC_000371897

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000371897Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →