Mr Bernard P. Orlan July 3, 2002 Air Sampling for Metals Page 2 P.S. 234fManhattan) ATC Project No. 15-19125-0279

Results

May 7

The metals that were found in the samples above the limits of detection were chromium (Cr) and iron (Fe). (/hromium and lead (Pb) were detected in the blanks (Pb was not detected in the samples). The other nine metals were not detected

Blank-correcting the Cr concentrations (blank average: 0.713 micrograms per filter) reduces them to below or just above4 the limit of detection.

Iron (Fe) was detected in the samples from the Main Lobby at 2.74 micrograms per cubic meter (2.74 ug/m’) and the West Playground at 2.37 ug/m’.

May 14

The metals detected on this date were Cr and aluminum (Al). Cr was detected in all four samples and the blanks. Blank-correcting the Cr concentrations of the samples (blank average 0.646 ug/filter) reduces them below the limit of detection.

Al was detected in the sample from the Main Lobby at 0.868 ug/m\ It was not found in the other samples or in the blanks.

May 21

The metals detected in these samples were Al, Cr, copper (Cu), Fe and Pb. Only Cr was found in the blanks.

The blank-corrected Cr concentrations of the two indoor samples were 0.232 ug/m^ (#M1, Lobby-Main Entrance) and 0.110 ug/m’ (#M2, 1” Floor Hall-Center). The Lobby-Main Entrance sample also contained Al (1.00 ug/m'), Fe (1.81 ug/m’) and Pb (0.258 ug/m’). Pb was detected in the T‘ Floor Hall sample at 0.255 ug/m’.

Al and Cu were detected in the Roof sample (#M4) at 1.05 ug/m’ and 2.02 ug/m\ respectively.

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium (the more toxic form) in air of 0.6 micrograms per cubic meter of air (ug/m’), this assumes a continuous exposure for one year. These samples were analyzed for total chromium (trivalent and hexavalent). All Cr concentrations were below the EPA screening level.

The EPA’s ambient air standard for lead (Pb) is 1.5 ug/m’ (three-month average). The Pb concentrations were below the EPA standard.

The EPA has no standard or screening level for Al, Cu or Fe in ambient air.

CITY_21MC100_002867600

NYC-WTC_000371762

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000371762Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →