NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Memo: Air sampling for metals, P.S.89M, Feb 2002

Machine-extracted title · confidence 50%

March 15, 2002 memo describing air sampling at P.S. 89M.

NYC-WTC_000326546–000326548
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan Marchis, 2002 Air Sampling for Metals Page 2 P.S. 89 (Manhattan') ATC Project No. 15-19125-0297

Results

The metals that were found above the limits of detection were aluminum (Al), chromium (Cr), iron (Fe), lead (Ph) and magnesium (Mg). The other metals were not detected. The table shows the locations and concentrations at which Al, Cr, Fe, Pb and Mg were detected. Cr and Pb were detected in the blank. Subtracting the blank concentrations from those found in the samples reduces the actual levels considerably. The blank-corrected metal concentrations are shown in the table.

METALS IN AIR CONCENTRATIONS FEBRUARY 28, 2002 (Blank-corrected) (ug/m^ *) LOCATION/SVMPI ■ I.CJ M inncsiuiii _________ ________ _______ \ ____________

Floor Hallway by 0.953 BDL** BDL BDL BDL Cafeteria/Ml

Playground (north 1.35 BDL 1.80 BDL 1.19 side)/M2

Playground (south 1.68 0.023 BDL BDL BDL sidc)/M3

Roo6'M4 BDL 0.059 BDL 0.030 BDL

Blank/M5 (ug/sample) BDL 0.459 BDL 0.335 BDL I I micrograms per cubic meter of air ** Below Detection Limit

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium (the more toxic form) in air of 0.6 ug/m^, this assumes a continuous exposure for one year. . The samples here were analyzed for total chromium (trivalent and hexavalent). The concentrations in the two outdoor samples are below the EPA level. Chromium was Ko/ detected indoors.

The EPA has established an ambient air standard for lead of 1.5 ug/m^ based on a three-month exposure. That is 50x’s the concentration detected in the one sample here (M4). This was an outdoor sample, Pb was,not detected indoors.

Aluminum was the only metal detected indoors. Magnesium and iron were detected only in one outdoor sample (M2). The EPA has no published screening level or guideline for aluminum, iron or magnesium.

CITY_21MC100_005390213

NYC-WTC_000326547

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000326547Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →