Air sampling for metals, Stuyvesant HS

Machine-extracted title · confidence 32%

ATC letter report of metals air sampling at Stuyvesant High School, May–June 2002.

NYC-WTC_000407123–000407125
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan July 1,2002 Air Sampling for Metals Page 2 H.S. for l.eadership & Pub. Service (894M) ATC Project No. 15-19125-0290 Results

MayJ. Chromium (Cr) was detected in all four samples, and both blank samples. Lead (Pb) was detected in three of the four samples (main lobby, 10'*' floor by elevator and on the roof) and both field blanks. Blank-correcting the Cr and Pb concentrations in the samples lowers them to below the limits of detection.

^dayJJl Chromium (Cr) was detected in all four samples and both blank samples. Aluminum (Al) was also detected in all four samples but not in the field blanks. Blank-correcting the Cr concentrations in the samples lowers them to below the limits of detection. The LfSEPA has no screening level for aluminum.

MajLlZ

The metals that were found above the limits of detection were aluminum (Al), chromium (Cr), copper (Cu), iron (Fe), lead (Pb), magnesium (Mg), and Zinc (Zn). The other metals were not detected. The table shows the locations and concentration.s at which Al, Cr, Cu, Fe, Pb, Zn, and Mg were detected. Al, Cr, Fe, and Pb were detected in the blank. Subtracting the blank concentrations from those found in the samples reduces the actual levels considerably. The blank-corrected metal concentrations are shown in the table. METALS IN AIR CONCENTRATIONS May 17,2002 (Blank-corrected) (ug/m’ *) teia ^Maga^rum ■SAMPLI^O.;3 Y

Main lobby BDL** 0.143 BDL BDL BDL BDL BDL /Ml

5* Floor Elev BDL 0.179 BDL -1.39 -0.0116 BDL BDL Lobby/M2

lOthFloor Elev BDL -0.029 BDL -0.65 -0.0067 BDL BDL /M3

RoofZM4 2.26 0.580 0.646 2.45 0.4 0.781 2.36

Blank/M5 BDL 0.733 BDL 3.97 0.344 BDL BDL (ug/sample)

Blank/M6 1.03 0.826 BDL 6.91 0.323 BDL BDL (ug/sample) micrograms per cubic meter of air ** Below Detection Limit

CITY_21MC100_002903357

NYC-WTC_000407124

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407124Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000175567

Letter report detailing air sampling for metals conducted at the High School for Leadership on multiple dates between May and June 2002.

Similar indexed content

NYC-WTC_000175577

Letter report detailing air sampling for metals conducted at the High School for Leadership on dates in March 2002.

Similar indexed content

Compare copies and versions →