Air sampling report, Silica, High School for Leadership, 2002

Machine-extracted title · confidence 58%

ATC sampling report for silica at a NYC high school in May 2002.

NYC-WTC_000370277–000370278
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St.. 10th Floor

.TC I ASSOCIATES INC. New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306

May 24, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North . Long Island City, NY 11101

Re: Air Sampling for Silica High School for Leadership and Public Service (M894) 90 Trinity Place New York, New York ATC Project No. 15-19125-0290

Dear Mr. Orlan;

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for silica-containing dust conducted on April 5 and 12, 2002, at the referenced school. The New York City Board of Education (BOE) requested this sampling to assess the concentration of crystalline silica in the respirable particulates within the building.

Scope of Work

On each day, ATC collected three (3) samples for respirable particulates using pre­ weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. All samples were collected indoors. The samples, plus one blank filter, were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. Analysis was performed by x-ray diffraction according to OSHA Method 142. A copy of the analytical report is attached.

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office, collected the samples consistent with generally accepted industrial hygiene practices. The results of the sampling represent conditions found on the date the samples were collected.

Samples were obtained in the 1“ Floor Main Lobby, the 5“’ Floor Hallway near the Elevator and the 10"' Floor Hallway near the Elevator.

CITY_21MC100_002865485

NYC-WTC_000370277

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000370277Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →