June 18, 2002
Mr. Bernard P. Orlan
Director, Environmental Health & Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101-4008
Re: Air Sampling for Silica
P. S. 234M
ATC Project No. 15-19125-0279
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of the results of air monitoring for
silica-containing dust conducted on April 23 and 30, 2002, at the referenced school. The New
York City Board of Education (BOE) requested this monitoring at the recommendation of
Environ Corp., the consultant to the parents association.
Scope of Work
On each day, ATC collected a total of seven (7) samples (and on^ blank) for respirable dust
using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger
(non-respirable) particles prior to deposition on the filters. All of the samples were collected
indoors. The samples were sent to PSC Analytical Services, Inc., an American Industrial
Hygiene Association accredited laboratory in Reading, PA. Analysis for silica was performed
by x-ray diffraction according to OSHA Method 142. Copies of the analytical laboratory reports
are attached.
Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office,
collected the samples consistent with generally accepted industrial hygiene practices. As with all
such sampling, there were inherent limitations created by constraints of time, operational and
work practice variability, variations in air contaminant concentrations and sampling and
analytical accuracy. The results of the sampling represent conditions found on the dates the
samples were collected.
Samples were collected in the following locations; 1^^ floor Hallway, Cafeteria, Gymnasium,
Auditorium, Room 315 (South), Room 323 (South) and Room 316 (facing East).